검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 27

        21.
        2018.10 서비스 종료(열람 제한)
        This study investigates the effects of compressive strengths on mechanical properties of concrete with compressive strengths of 40 and 80 MPa. In this study, The steel fiber an aspect ratio of 64 and a tensile strength of 1,600 MPa used. As the result, There are no significant effect of fiber tensile strength on mechanical properties of normal strength SFRC. For high strength SFRC, Specimen with high strength fiber have superior performance then that with normal strength fiber.
        22.
        2018.10 서비스 종료(열람 제한)
        This paper evaluates analytically the flexural behavior of steel fiber reinforced concrete (SFRC) notched beams according to the tensile strength of steel fiber. For this purpose, compressive strength and bending tests of SFRC applying steel fibers with tensil strength of 1,200 and 1,600 MPa was conducted. Strain hardening behavior was observed when using high tensile strength steel fiber. Compression and tensile models were established through test results. For the tensile model, hordijk model and trilinear model were analyzed and compared. The results of analysis showed good agreement when using trilinear model.
        23.
        2018.10 서비스 종료(열람 제한)
        This paper describes the effect of steel fiber volume fraction and aspect ratio on mechanical properties of SFRC with compressive strength of 40 MPa. In this study, The fiber volume fractions consist of 0.25%, 0.50% and 0.75% and aspect ratios are 64 and 80 used. The prisms with 150×150×550 mm were made and tested in accordance with EN-14651. Test results show that the superior flexural performance was observed in SFRC with higher fiber volume fraction and aspect ratio.
        24.
        2018.10 서비스 종료(열람 제한)
        This study was evaluated the chloride penetration resistance performance of Surface Protection Material(SPM). SPM was applied 0.25 and 0.51 kg/㎡ to the surface of the mortar and immersed aging of the chloride solution 7, 14, and 28 days. As a results, In the case of SPM was applied, chloride did not penetrate until the 28th day.
        25.
        2018.10 서비스 종료(열람 제한)
        In this study, the rate of change of electrical resistance with respect to the strength and load of cement composites was investigated by incorporating Carbon Nanotube(CNT) at 0.25, 0.5, 0.75, 1.0% of the binder weight. Compressive strength test It was shown that the load of 30% was repeatedly applied to impart conductivity through the rate of change of electrical resistance. The incorporation rate of CNT greatly affected the compressive strength and the rate of change of electrical resistance.
        26.
        2018.10 서비스 종료(열람 제한)
        This paper was conducted to investigate analytically the non-ductile reinforced concrete frame and steel frame. The results of cyclic loading test and analysis was compared. The maximum strength and strength reduction point of test result were similar to analysis result.
        27.
        2017.04 서비스 종료(열람 제한)
        This paper examines the effect of steel fiber volume fraction on compressive and flexural properties of high-strength concrete with compressive strength of 40 MPa. The fiber volume fractions used in this study consist of 0.5, 0.75 and 1.0%. The prisms with 150x150x550 mm were made and tested in accordance with EN-14651.
        1 2