        1.
        2009.03 구독 인증기관 무료, 개인회원 유료
        A improved strength model was developed to predict the punching shear strength of interior slab-column connections without shear reinforcement. Considering the damage due to flexural cracking at slab-column connections damaged by flexural cracking, the punchingshear force was assumed to be resisted mainly by the compression zone of the critical section. The punching shear strength was defined by using the material failure criteria of concrete. In the evaluation of the punching shear strength, the interaction between the shear stress and the compressive normal stress developed by the flexural moment of the slab was considered. The proposed strength model was verified by existing test specimens.
        4,000원
        2.
        2013.09 서비스 종료(열람 제한)
        대상구조물은 준공 후 6년 경과된 창고용도의 구조물로서 폭설이 내리는 도중 창고 지붕(Arch Panel)과 서측에 면한 기둥 및 벽체부분이 붕괴사고가 발생됨에 따라 붕괴원인과 붕괴사고 후 남아있는 구조체의 안전성 여부를 확인하기 위하여 건물주의 요청에 의해 정밀안전진단을 실시하게 된 것이다. 따라서, 관련된 도면 및 현재 시공상태를 비교 검토하고 붕괴된 부분과 붕괴되지 않은 구조물에 대해 외관조사와 비파괴조사(콘크리트 강도시험, 철근배근탐사 등)를 수행하여 구조부재의 상태와 손상정도를 파악한다. 또한, 지붕 및 기둥 붕괴에 관련한 하중을 검토하여 구조물의 안전성여부를 확인하기 위해 구조검토를 수행한다. 수행된 결과들을 종합적으로 검토하여 붕괴원인을 검토 분석하고 붕괴되지 않은 부분에 대한 보수⋅보강 여부를 제시하는 것을 목적으로 한다.