Recently, in newly constructed apartment buildings, the exterior wall structures have been characterized by thinness, having various openings, and a significantly low reinforcement ratio. In this study, a nonlinear finite element analysis was performed to investigate the crack damage characteristics of the exterior wall structure. The limited analysis models for a 10-story exterior wall were constructed based on the prototype apartment building, and nonlinear static analysis (push-over analysis) was performed. Based on the finite element (FE) analysis model, the parametric study was conducted to investigate the effects of various design parameters on the strength and crack width of the exterior walls. As the parameters, the vertical reinforcement ratio and horizontal reinforcement ratio of the wall, as well as the uniformly distributed longitudinal reinforcement ratio and shear reinforcement ratio of the connection beam, were addressed. The analysis results showed that the strength and deformation capacity of the prototype exterior walls were limited by the failure of the connection beam prior to the flexural yielding of the walls. Thus, the increase of wall reinforcement limitedly affected the failure modes, peak strengths, and crack damages. On the other hand, when the reinforcement ratio of the connection beams was increased, the peak strength was increased due to the increase in the load-carrying capacity of the connection beams. Further, the crack damage index decreased as the reinforcement ratio of the connection beam increased. In particular, it was more effective to increase the uniformly distributed longitudinal reinforcement ratio in the connection beams to decrease the crack damage of the coupling beams, regardless of the type of the prototype exterior walls.
Objective : Dementia prevention program has been applied in Center for dementia by the occupational therapists. We evaluated the efficacy of this program to the elderly non-demented women in senior citizens center for cognitive, physical function and depression.Methods : We applied this program to women subjects from a senior citizens centers in 12 sessions. Cognitive and physical functions and depression were compared between pre and post-intervention with Korean Mini-Mental State Examination (K-MMSE), Timed-Up and Go test (TUG), One Leg Standing Test (OLST) and Geriatric Depression Scale Short Form-Korea version (GDSSF-K).Results : We enrolled 26 non-dementia women from four senior citizens centers in Seoul Yangcheon-gu. The K-MMSE improved after the dementia prevention program significantly (p=.00). The GDSSF-K was significantly different between pre and post-intervention (p=.02). For physical function, TUG (p=.02) and OLST in opening eyes were significantly improved (respectively, p=.00 in right side, and p=.00 in left side). OLST in closed eyes were tend to be improved after the intervention, however, they were not significantly different.Conclusion : The dementia prevention program of Center for dementia has proved to improve cognitive and physical function and to reduce depression in the non-demented women from senior citizens centers. These findings suggest that the dementia prevention program that has led by occupational therapist in Center for dementia can be applied other setting in a community.
In this paper, a new waffle-shaped(WAS) precast concrete panel was developed through the geometrical modification of the conventional double tee panel. It is a one-way joisted panel with a shallow depth and a boxed shape by wide edge beams. To investigate the structural performance of the connections between W AS panels, loading tests called by WIW were performed at the connections along short edges of two WAS panels. WIW tests were executed according to two different width of shear key(50mm and 80mm) and three types of reinforced topping concrete(wire-mesh alone, wire-mesh plus HD 10, and wire-mesh plus HD13). As a result, the grouting width of shear keys did not act on the ultimate behaviors significantly, and the flexural strength of WIW connections along the long edges of W AS panels was superior to nominal flexural strength. The connections with proper details of steel reinforcement can distribute the positive bending moment at mid-span of W AS panels to the negative moment, which is useful for efficient member design.
국내의 경우 아파트 등 공동주택의 안전점검과 진단은 2-6년 주기로 수행되고 있다. 하지만 최근 2016년 이후의 안전점검 및 진단 용역의 적법 수행여부에 대한 정부합동점검결과, 공동주택의 부실수행 비율이 매우 높다. 이는 공동주택의 경우 법정 대가기준 대비 평균 1-10% 수준에서 용역이 낙찰되기 때문인 것으로 분석된다. 본 연구에서는 공동주택의 안전전검 및 진단에 대한 결과조사를 바탕으로 업체형태, 협약방식 별로 협약대가, 조사 및 시험의 충실성 등 현황을 분석하였다. 조사대상은 년도, 규모, 지역 등 다양한 변수 분포를 가지며, 이를 바탕으로 공동주택의 안전점검 및 진단의 부실 현황을 분석하였다.
국내의 경우 아파트 등 공동주택의 안전점검과 진단은 주기적으로 수행되고 있지만 부실수행의 비율이 매우 높다. 현재 국내 공동주택 안전점검-진단 세부지침 및 해설서는 시설물 일반 그리고 건축물 일반과 표본층수 산정 방법과 재료시험 수행개수 등이 동일하다. 그러나 공동주택은 일반 건축물과 달리 생애주기 동안에 용도변경이 거의 없으며 하중의 편차가 크지 않는 특성이 있다. 특히 지상 또는 지하주차장의 면적이 넓고 형태가 다양하며, 건설년도에 따라서 지하주차장 시스템이 달라지고 있다. 한편 공동주택은 벽식구조와 골조식 구조로의 전이부가 있거나, 콘크리트의 강도가 건축물 상하부에서 달라 지는 등 여러 가지 고유의 특징을 가지고 있다. 본 연구에서는 공동주택의 주요 특징을 고려하여 공동주택 안전점검 및 진단의 수행방법 개선을 위한 방안을 제안하였다.
구조물에 최적화된 센서 배열(Sensor Array)을 수행하는 것은 센서 네트워크 설계에서 중요한 요소이다. 그러나 센서의 설치와 관리는 구조물이 처해 있는 환경이나, 경제성 그리고 센서의 주파수대역의 제한과 같은 다양한 원인으로 인해 매우 어려울 수 있다. 이 논문에서는 일반적인 문제와 환경에서 현재 사용되고 있는 물리적 센서 대용으로 가상 시각 센서(VVS: Virtual Visual Sensor)를 제안하였다.
가상 시각 센서는 설치가 간편하고 경제적이며 관리가 편하다는 큰 장점을 가지고 있다. 이러한 가상 시각 센서의 기본적인 아이디어는 최첨단 컴퓨터 시각 알고리즘과 마커 추출 기법의 적용으로 이루어진다. 이 연구에서는 가상 시각 센서를 이용하여 모드 형태와 주파수를 추출하는데 용이하다는 점을 보여주며 이를 구조물 건전성 모니터링에 적용할 경우 효율적이라는 점을 입증하였다.
대상구조물은 준공 후 6년 경과된 창고용도의 구조물로서 폭설이 내리는 도중 창고 지붕(Arch Panel)과 서측에 면한 기둥 및 벽체부분이 붕괴사고가 발생됨에 따라 붕괴원인과 붕괴사고 후 남아있는 구조체의 안전성 여부를 확인하기 위하여 건물주의 요청에 의해 정밀안전진단을 실시하게 된 것이다. 따라서, 관련된 도면 및 현재 시공상태를 비교 검토하고 붕괴된 부분과 붕괴되지 않은 구조물에 대해 외관조사와 비파괴조사(콘크리트 강도시험, 철근배근탐사 등)를 수행하여 구조부재의 상태와 손상정도를 파악한다. 또한, 지붕 및 기둥 붕괴에 관련한 하중을 검토하여 구조물의 안전성여부를 확인하기 위해 구조검토를 수행한다. 수행된 결과들을 종합적으로 검토하여 붕괴원인을 검토 분석하고 붕괴되지 않은 부분에 대한 보수⋅보강 여부를 제시하는 것을 목적으로 한다.
강섬유보강 초고성능 콘크리트(UHPC)는 압축강도가 200MPa에 이르고, 강성 및 인성이 크기 때문에 이를 이용하면 구조 부재를 얇고 가볍게 설계하는 것이 가능하다. 본 논문은 UHPC를 교량의 바닥판 슬래브에 적용하기 위해서 뚫림전단(punching shear)에 대한 저항능력을 평가한 것이다. 6개의 정사각형 슬래브를 제작하여 4변 완전고정 상태에서 뚫림전단 실험을 수행하였다. 슬래브의 두께는 40mm와 70mm였고, 재하판의 형상비는 1.0~2.5 범위였다. 40mm 실험체는 최대하중 이후에 연성적인 변형률 연화구간이 길고, 70mm 실험체는 상대적으로 더 취성적인 뚫림파괴를 보였다. 기존의 여러 뚫림전단강도 평가식을 이용하여 실험결과를 분석하였는데, 두께가 작은 40mm 실험체에서는 DuctalⓇ 및 JSCE의 식이, 그리고 70mm 실험체에서는 Harajli et al. 및 ACI-DuctalⓇ의 제안식이 상대적으로 실험에 근접한 값을 예측하였다. 그러나 전반적으로 실험결과를 잘 예측하지 못하였으므로 실제 파괴메커니즘에 근거한 새로운 식을 제안하였다. 새로 제안한 식은 실험결과를 비교적 잘 예측하는 것으로 나타났다.