        1.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Tensile load tests were conducted on High-Shear Ring Anchors (HRAs) after shear load had been applied to the HRAs, which had been developed to reduce the number of the anchors. Test variables include the embedment length of the rod and the width of the specimens and a total of 12 specimens were tested. Test results show that the HRAs pulled out due to bond failure or steel failure occurred in case that the HRAs were installed to the members with 300mm or greater width and the embedment length of 160mm (the actual embedment of rod is 140mm) or deeper. Except 4 HRAs showing steel failure of rod, the minimum and average of test-to-prediction by ACI 318-14 ratios are 1.18 and 1.79, respectively. The tensile strength of HRAs, after shear load was applied to the HRAs, can be safely evaluated by the minimum among the concrete breakout strength and bond strength with the actual embedment length of the rod.
        4,000원
        2.
        2019.10 서비스 종료(열람 제한)
        기존 구조물의 리모델링, 내진보강 및 용도변경에 따른 구조 보강의 수요가 증가하고 있다. 기존에는 내진보강 공법으로 전단벽 증설 또는 신설방식의 보강 공사가 주를 이루었다. 하지만, 최근에는 시공적인 측면과 전단벽 신설 시 발생하는 기초 보강을 최소화하기 위해 강재를 이용한 건식 내진보강 공법이 증가하고 있다. 신구 콘크리트 부재 연결을 위한 고전단 링앵커와, 기존 콘크리트와 신규 강재 접합용 고전단 링앵커를 개발되었다. 개발 후 학교 건축물을 비롯하여 다수의 실제 프로젝트에 적용되었으며, 구조효율성과 시공성 우수성이 검증되었다. 이 발표에서는 콘크리트용 및 강재용 고전단 링앵커의 설계 와 시공 사례를 소개하고자 한다.
        3.
        2019.10 서비스 종료(열람 제한)
        후설치앵커는 굳은 콘크리트 부재에 설치되어 구조 부재간의 하중 전달 또는 비구조요소의 하중을 구조부재로 전달하는데 사용된다. 국내 후설치앵커는 2007년 콘크리트구조기준 개정에 처음 신설되었으며 기계식 후설치앵커의 설계법만 규정하였다. 2018년 10월 기준 개정에서는 부착식 후설치앵커 설계법도 추가되었으며 특히 부록에서 본문 22장으로 이동하였다. 2020 년 국가건설기준으로 반영되면 법적 기준의 지위를 갖게된다. 내진보강, 구조보강, 증축 및 리모델링을 비로한 구조 요소간 접합뿐 아니라 기계전기설비와 마감재 등 비구조요소를 구조부재에 연결에도 후설치앵커가 많이 사용된다. 이 연구에서는 구조기준의 개정사항을 분석하여 안전하고 경제적인 후설치앵커 설계방법을 제시하고자 한다.
        4.
        2019.10 서비스 종료(열람 제한)
        국내의 경우 아파트 등 공동주택의 안전점검과 진단은 2-6년 주기로 수행되고 있다. 하지만 최근 2016년 이후의 안전점검 및 진단 용역의 적법 수행여부에 대한 정부합동점검결과, 공동주택의 부실수행 비율이 매우 높다. 이는 공동주택의 경우 법정 대가기준 대비 평균 1-10% 수준에서 용역이 낙찰되기 때문인 것으로 분석된다. 본 연구에서는 공동주택의 안전전검 및 진단에 대한 결과조사를 바탕으로 업체형태, 협약방식 별로 협약대가, 조사 및 시험의 충실성 등 현황을 분석하였다. 조사대상은 년도, 규모, 지역 등 다양한 변수 분포를 가지며, 이를 바탕으로 공동주택의 안전점검 및 진단의 부실 현황을 분석하였다.
        5.
        2019.10 서비스 종료(열람 제한)
        국내의 경우 아파트 등 공동주택의 안전점검과 진단은 주기적으로 수행되고 있지만 부실수행의 비율이 매우 높다. 현재 국내 공동주택 안전점검-진단 세부지침 및 해설서는 시설물 일반 그리고 건축물 일반과 표본층수 산정 방법과 재료시험 수행개수 등이 동일하다. 그러나 공동주택은 일반 건축물과 달리 생애주기 동안에 용도변경이 거의 없으며 하중의 편차가 크지 않는 특성이 있다. 특히 지상 또는 지하주차장의 면적이 넓고 형태가 다양하며, 건설년도에 따라서 지하주차장 시스템이 달라지고 있다. 한편 공동주택은 벽식구조와 골조식 구조로의 전이부가 있거나, 콘크리트의 강도가 건축물 상하부에서 달라 지는 등 여러 가지 고유의 특징을 가지고 있다. 본 연구에서는 공동주택의 주요 특징을 고려하여 공동주택 안전점검 및 진단의 수행방법 개선을 위한 방안을 제안하였다.
        6.
        2019.04 서비스 종료(열람 제한)
        For the purpose of increasing slab span, new composite beam with U-shaped compression element consisting of channel and concrete has been developed. Strength design procedures of the composite beam against construction and permanent loads have been proposed. Using these procedures, it is possible to design consistently of the developed composite beam.
        7.
        2019.04 서비스 종료(열람 제한)
        Based on the construction plan of a high-rise residential building, a case study for shear design of horizontal construction joint of transfer plate. Design to resist real shear force was proposed to enhance an efficiency of construction of transfer plate.
        8.
        2014.04 서비스 종료(열람 제한)
        If the bracket triangle are commonly used, you may issues such as withdrawal caused by mounting unstable bracket phenomena and bending wire, the eccentricity of the loading plate than steel when you change the angle of the hole during construction will occur. SM brackets adjustment of the angle of 25~40 degrees is possible adjustment of the angle of the ground anchor bracket arched surface, the change in distance between the fixing position of the line and band pieces, due to changes in the installation angle, designers from steel Unlike with the intention, it is possible if the corresponding method can be constructed. Also, For construction of temporary structure used anchor, it will be reinforced with stiffener to prevent excessive deformation of the wale. In general, the welded steel stiffener is used. Construction of welded steel stiffener is costly and time-consuming and cause the problem that wale does not reuse. In order to solve these problems, various kinds of non-weled stiffeners are being developed.
        9.
        2013.10 서비스 종료(열람 제한)
        For construction of temporary structure used anchor, it will be reinforced with stiffener to prevent excessive deformation of the wale. In general, the welded steel stiffener is used. Construction of welded steel stiffener is costly and time-consuming and cause the problem that wale does not reuse. In order to solve these problems, various kinds of non-weled stiffeners are being developed. In this paper, non-welded and conventional welded stiffener for maximum strength, fracture pattern and the residual stregth due to cyclic loading is to evaluate.