검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 12

        1.
        2024.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, in newly constructed apartment buildings, the exterior wall structures have been characterized by thinness, having various openings, and a significantly low reinforcement ratio. In this study, a nonlinear finite element analysis was performed to investigate the crack damage characteristics of the exterior wall structure. The limited analysis models for a 10-story exterior wall were constructed based on the prototype apartment building, and nonlinear static analysis (push-over analysis) was performed. Based on the finite element (FE) analysis model, the parametric study was conducted to investigate the effects of various design parameters on the strength and crack width of the exterior walls. As the parameters, the vertical reinforcement ratio and horizontal reinforcement ratio of the wall, as well as the uniformly distributed longitudinal reinforcement ratio and shear reinforcement ratio of the connection beam, were addressed. The analysis results showed that the strength and deformation capacity of the prototype exterior walls were limited by the failure of the connection beam prior to the flexural yielding of the walls. Thus, the increase of wall reinforcement limitedly affected the failure modes, peak strengths, and crack damages. On the other hand, when the reinforcement ratio of the connection beams was increased, the peak strength was increased due to the increase in the load-carrying capacity of the connection beams. Further, the crack damage index decreased as the reinforcement ratio of the connection beam increased. In particular, it was more effective to increase the uniformly distributed longitudinal reinforcement ratio in the connection beams to decrease the crack damage of the coupling beams, regardless of the type of the prototype exterior walls.
        4,200원
        3.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        현 설계기준에서 제시한 단부횡보강 상세는 시공성과 생산품질이 현저히 떨어지므로 내진성능과 시공성을 확보할 수 있는 RC 구 조벽체의 단부횡보강 상세 개발이 필요하다. 최근 선재 제작기술의 발전으로 다양한 선조립철근의 제작이 가능해지고 있으며 특히 다양한 연속횡보강 철근 상세의 제작이 가능하게 되었다. 본 연구에서는 사각 연속횡보강 선조립철근 단부횡보강 상세를 적용한 RC 구조벽체의 모멘트-곡률 관계에 대한 분석을 진행하였다. 비선형 단면해석에 의하면 사각 연속횡보강의 상세를 적용한 RC 구조벽체 는 사각 연속횡보강 영역의 면적이 증가할수록 내진성능을 확보할 수 있다. 이러한 연구결과에 근거하여 사각 연속횡보강 선조립 철 근의 상세 적용시, 단부횡보강 영역의 면적만큼 사각 연속횡보강 영역의 면적을 확보해야 한다.
        4,200원
        4.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 현장작업을 최소화할 수 있는 PC(Precast Concrete) 건축공법의 적용이 급속하게 활성화되고 있다. 그러나 PC 공법은 시공 중, 특히 부재간 일체화 이전에 구조적 성능을 발휘하기 어렵고 완공 후에도 접합부의 일체성을 확보하기 어려워 연쇄붕괴에 취약하다. PC 건축물에서는 다양한 PC 부재간 접합 상세가 존재하며, 국내외 구조/시공 상세가 현격히 다르다. 그러나 국내 PC 시스템의 시스템 과 상세 특성을 반영한 연쇄붕괴에 대한 연구는 매우 미비하다. 따라서, 본 연구에서는 국내에서 주로 사용하는 PC 구조시스템과 접 합부 구조/시공 상세를 조사 분석하였다. 이를 기반으로 국내에서 사용되는 전형적인 PC 시스템의 유형을 설정하고 상기 PC 시스템 의 연쇄붕괴방지성능을 평가하기 위하여 비선형 유한요소해석을 수행하였다. 해석결과를 바탕으로 국내에서 주로 사용된 PC 구조시 스템의 연쇄붕괴방지 성능을 평가하고 구조설계시 고려사항을 제안하였다.
        4,000원
        5.
        2021.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이상의 결과를 종합하면, 혼합유산균 2종(Bifidobacterium animalis ssp. Lactis Bf141와 Lactobacillus rhamnosus Lb102)의 섭취는 고지방식이 유도 비만 마우스에서 체중, 체지방, 제지방, 골밀도 등 주요 체성분에 영향을 주지 않았다. 혼합유산균은 식욕 조절 효과를 위해 측정한 사료 섭취량에도 영향을 주지 않았으며, 간 조직 무게에도 영향을 미치지 않았다. 인슐린저항성과 포도당신생합성의 주요 지표인 공복혈당량 또한 혼합유산균 급여에 의해 변화 하지 않았다. 또한 혼합유산균은 심혈관질환의 지표로 사용되는 혈중 중성지방 및 총 콜레스테롤에 영향을 주지 않았으며, 체내 지방의 소화 및 흡수율에서도 영향을 미치지 않았다. 결론적으로, 고지방식이유도 비만 마우스를 이용하여 혼합유산균(Bf141 + Lb102)의 항비만 생리활성 을 검증한 결과, 유의미한 물리적, 대사적 표현형 개선은 검증되지 않았다. 따라서, 추후 개별 보다 다양한 혼합 조건 및 농도로 연구를 설계하여 혼합유산균의 항비만 효과를 검증할 필요성이 있다.
        4,000원
        7.
        2020.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, the use of transfer slab system has increased greatly. However, several construction problems are being encountered owing to its excessive thickness. Therefore, in this study, a transfer slab system that uses a reverse drop panel, which can utilize the facility space of the pit floor by reducing the transfer slab thickness, was considered. To investigate the shear behavior of transfer slab system that uses the reverse drop panel, the two-way shear strength of transfer slab-column connection with the reverse drop panel was analyzed using nonlinear FE analysis. In addition, the two-way shear strength evaluations of transfer slab with the reverse drop panel conducted using the existing evaluation methods were verified by comparing the strengths predicted by those methods with the results of nonlinear FE analysis.
        4,000원
        8.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 국내에서는 고층 벽식 아파트 건설 시, 하부 주차공간과 공용공간 확보를 위하여 RC 전이슬래브 시스템을 사용하는 경우가 증가하고 있다. 하지만 두께가 얇은 RC 무량판 슬래브를 위해 개발된 설계방법 및 구조성능평가 방법을 두께가 매우 두꺼운 전이슬래브 구조설계에 그대로 사용하고 있다는 문제점이 있다. 따라서 합리적인 전이슬래브의 구조설계를 위해서는 RC 전이슬래브 시스템의 2면 전단거동 양상에 대한 명확한 분석이 필요하다. 이에 따라 본 연구에서는 전이슬래브의 두께, 콘크리트 강도, 전단경간비, 철근비 등 다양한 설계변수에 따라 비선형 FEM을 이용하여 전이슬래브의 2면 전단거동을 분석 하였다. 또한 비선형 FEM 해석결과와 기존의 2면 전단강도 평가식으로 예측한 전단강도를 비교분석하여 기존 평가식의 전이슬래브 2면 전단강도 평가 유효성을 검토하였다.
        4,800원
        9.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 다양한 변수를 갖는 병렬 RC 구조벽체시스템에 대한 성능기반설계의 타당성과 이에 따른 모멘트 재분배 개념의 적용성을 분석하기 위해 횡력을 지지하는 병렬 RC 구조벽체시스템에 대한 비선형해석을 수행하였다. 설계변수(철근 비, 콘크리트변형률, 벽체높이)가 병렬 RC 구조벽체시스템의 거동에 미치는 영향을 분석하였으며 이를 기반으로 병렬 RC 구조벽체시스템의 성능기반 설계를 위한 고려사항을 제안하였다. 비선형해석 결과, 병렬 RC 구조벽체시스템 성능기반 설계 와 모멘트 재분배 개념의 적용을 위해서는 연결보의 항복여부에 대한 고려가 필요한 것으로 나타났다. 높은 벽체의 경우, 연 결보가 항복하지 않고 탄성 상태로 거동할 수 있기 때문에 고층 병렬 RC 구조벽체시스템에 대해 성능기반 설계 및 모멘트 재분배 개념을 적용하기 위해서는 벽체에 높은 수준의 소성변형능력을 필요로 하며, 이를 위해 벽체 압축단부에 횡보강을 필수적으로 실시해야 한다.
        4,200원
        10.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        일반적으로 건축물의 구조해석과 설계에 있어 작업효율을 확보하기 위하여 상부구조물과 하부구조물을 별도로 모델링하여 해석 및 설계를 진행하는 분리해석 방법을 사용한다. 하지만, 상기 분리해석을 사용할 경우, 상부구조물의 고정지점과 변형된 기초구조물과는 실제 연결된 지점에서 변위차가 발생하여 구조해석의 기본요건인 변형적합성 조건을 만족하지 못하게 되고 상부구조-하부구조의 상호작용을 고려하지 못하기 때문에 실제와는 다른 구조해석 및 설계결과를 초래할 수 있다. 본 연구에서는 초고층 철골구조물을 대상으로 구조물의 부등침하 등에 큰 영향을 미치는 상재(常載)하중에 대한 분리해석과 일체해석의 해석결과 차이를 비교 분석하였다. 분석결과에 따르면 분리해석방법을 사용할 경우, 상부구조물의 구조해석에 있어 기초의 변형을 고려하지 못하기 때문에 부재력을 과소평가할 수 있고 이로인해 비안전측 설계결과를 가지고 올 수 있다. 하부 기초구조물을 분리해석으로 해석하였을 경우, 상부구조물의 강성을 고려하지 못하기 때문에 기초의 부등침하 과대평가, 부재력의 과대/과소 평가를 초래할 수 있어 비경제적이고 불안전한 설계결과를 가져올 수 있다. 특히, 기초의 변형이 상부구조물에 큰 영향을 미칠 수 있는 건축구조물, 지반의 강성이 작아서 기초에 큰 변형이 예상되는 건축물, 지반조건이 불균질하여 부등침하가 예상되는 건축구조물 등에는 분리해석을 지양해야 할 것이다.
        4,000원
        11.
        2010.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PC(Precast Concrete) 구조시스템은 건식화 조립식 공법으로 구조물 건설에 있어 공기, 노동력 절감 등의 여러 장점을 가지고 있다. 하지만 구조벽체의 경우 이를 PC화하여 사용할 경우 접합부의 내진성능이 떨어지므로 PC 구조벽체를 사용하는 경우는 드물다고 할 수 있다. 본 연구에서는 이러한 점을 감안하여 접합부 성능을 개선하여 횡력저항요소로 사용가능한 2종류의 PC 구조벽체를 제안하였다. 제안된 PC 구조벽체는 RC 벽체 및 PC 벽체가 혼합된 복합 PC 벽체와 벽체하부 연결철근의 일부를 단면감소시키고 비부착상세를 적용한 PC 벽체로서 지진발생 시 충분한 강도와 변형능력을 확보할 수 있도록 하였다. 제안된 PC 구조벽체의 내진성능평가를 위하여 RC 벽체를 포함한 3가지 벽체에 대한 실험체를 제작하여 주기 횡하중 실험을 수행하였다. 실험결과, 제안된 PC 구조벽체는 강도, 강성, 변형능력 및 에너지 소산능력이 기존 PC 구조벽체보다 월등히 향상되어 우수한 내진성능을 확보할 수 있는 것으로 나타났다.
        4,300원
        12.
        2012.01 KCI 등재 서비스 종료(열람 제한)
        최근 PC 공법을 도입하려는 시도가 많이 이루어지고 있다. 그러나 PC 벽체에 대한 연구는 개발의 어려움이 있어 상대적으로 더디게 발전되어 왔다. 본 연구에서는 PC벽체의 기존의 접합부의 시공성 및 구조성능을 개선하기 위하여 수직접합부의 개선안을 개발하였고, 이에 대한 구조성능평가를 진행하였다. 제안된 PC벽체의 수직접합부 구조적인 성능을 검증하기 위하여 반복적인 횡하중 재하시험을 진행한 결과, 기존의 일체형 PC벽체와 동등이상의 내진성능을 발휘하는 것으로 나타나 향후 구조물의 주요 횡력저항요소로 충분히 적용가능할 것으로 판단된다.