검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 3

        1.
        2022.10 구독 인증기관·개인회원 무료
        This study presents a rapid and quantitative radiochemical separation method for Nb isotopes in radioactive waste samples from the nuclear power plant with anion exchange resin after Fe coprecipitation. After radionuclides were leached from the radioactive waste samples with concentrated HCl and HNO3, the Nb isotopes were coprecipitated with Fe after filtering the leaching solution with 0.45 micron HA filter, while the Sr, Tc and Ni isotopes were in the solution. The Nb isotopes were separated in HCl medium with anion exchange resin. The purified Nb isotopes were measured using a low level liquid scintillation counter after installing quenching curve with standard Nb-94 isotopes. The separation method for Nb isotopes investigated in this study was applied to neutron dosimeter samples from the nuclear power plant after validating the Nb activity concentration with gamma spectrometry system.
        2.
        2022.05 구독 인증기관·개인회원 무료
        This study presents a rapid and quantitative sequential separation method for H-3 and C-14 isotopes with distillation apparatus in environmental samples released from nuclear facilities. After adding 200 mg of granulated potassium permanganate and 500 mg of sodium hydroxide in 100 mL of sample solution, the sample solution was heated until approximately 10 mL of distillate, and the distillate fraction was removed. The sample solution was heated again until a minimum 10 mL of additional distillate was collected. 10 mL of distillate was transferred to the LSC vail and the measurement sample for H-3 was made by adding 10 mL of Ultima Gold LLT to the LSC vial. After adding 2.5 g of potassium persulfate, 2 mL of 1M silver nitrate and 15 mL of concentrated nitric acid to the remained sample solution, the sample solution was heated for 90 minutes and C-14 isotopes were adsorbed into 10 mL of Carbo-Sorb solution in glass vial. The measurement sample for C-14 was made by adding 10 mL of Permafluor to the C-14 fraction in glass vial. The purified H-3 and C-14 samples were measured by the liquid scintillation counter after quenching correction. The average recoveries of H-3 and C-14 with CRM were measured to be 96% and 85%, respectively. The sequential separation method for H-3 and C-14 investigated in this study was applied to activated charcoal filter produced from nuclear power plants after validating the reliability by result of proficiency test (KOLAS-KRISS, PT-2021-51).