검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 3

        1.
        2022.10 구독 인증기관·개인회원 무료
        The decommissioning process of Kori Nuclear Power Plant No.1, which was permanently suspended in 2017, various studies and attention on the decommissioning of nuclear power plants and waste management are being focused. In particular, decommissioning of high-risk facilities should take into account both safety and economic aspects. Small defects in the decommissioning process may lead to major disasters, and the resulting economic losses will cause enormous damage at the national level. In order to prevent such damage, various decommissioning process simulations within a virtual environment should be performed, and process errors and results should be collected and analyzed through simulation to derive the optimal decommissioning scenario as possible. The platform introduced in this paper builds a virtual environment based on drawing and modeling data of Kori Nuclear Power Plant No.1 and automatically creates an optimized cutting path for dismantling the facility and internal structure, and simulates a cutting process similar to reality using Robot Arm. In addition, it is possible to derive and analyze a cutting process scenario by processing process results such as time required for work and cutting distance collected through simulation.
        2.
        2005.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The carbon nanofibers (CNFs) were synthesized through the catalytic decomposition of hydrocarbons in a quartz tube reactor. The CNFs prepared from C3H8 at 550℃ was selected as the purification sample due to the higher content of impurity than that prepared from other conditions. In this study, we carried out the purification of CNFs by oxidation in air or carbon dioxide after acid treatment, and investigated the influence of purification parameters such as kind of acid, concentration, oxidation time, and oxidation temperature on the structure of CNFs. The metal catalysts could be easily eliminated from the prepared CNFs by liquid phase purification with various acids and it was verified by ICP analysis, in which, for example, Ni content decreased from 2.51% to 0.18% with 8% nitric acid. However, the particulate carbon and heterogeneous fibers were not removed from the prepared CNFs by thermal oxidation in air and carbon dioxide. This result can be explained by that the direction of graphene sheet in CNFs is vertical to the fiber axis and the CNFs are oxidized at about the similar rate with the impurity carbon.
        4,000원
        3.
        2019.04 KCI 등재 서비스 종료(열람 제한)
        뇌신경계 인터벤션 시술은 장시간의 시술로 인해 피부의 수포, 탈모, 홍반 등의 방사선 피폭으로 인한 위해가 빈번히 보고되고 있다. 인체공학적으로 제작된 Bismuth (원자번호 83;Bi) 차폐체를 뇌혈관계 인터벤션 시술에 적용함으로써 의료방사선 피폭으로부터 두피 및 수정체의 방사선 피폭을 최소화하고자 하였다. 측정 부위는 4부위로 후두부(9 points), 양쪽 측두부(12 points), 양쪽 수정체부(6 points), 코 끝부(6 points)이며, 측정 소자는 광자극 형광 선량계(Optically Stimulated Luminescence Dosimeter: OSLD)를 각 지점(points)에 측 정기를 부착 후 자체 제작된 Bismuth차폐 기구를 사용 전(A그룹)과 후(B그룹)를 측정한 후 피부표면선량(en trance surface dose)을 비교 분석하였다. A 그룹(Bismuth unshield)과 B 그룹(Bismuth shield)의 피부선량 평균은 A 그룹은 92.44 mGy였고, B 그룹 은 67.55 mGy로 측정되었다. A 그룹에 비해 B 그룹에서 평균 26.92% 감소되었다. 후두부의 피부선량 평균은 A 그룹(9 point)은 146.08 mGy, B 그룹(9 point)은 103.23 mGy로 측정되었고 A 그룹에 비해 B 그룹에서 평균 29.32 % 감소하였다. 측두부의 피부선량 평균은 A 그룹(6 point)은 101.90 mGy, B 그룹(6 point)은 72.69 mGy로 측정되었고 A 그룹에 비해 B 그룹에서 평균 28.67% 감소하였다. 수정체부의 피부선량 평균은 A 그룹(3 point)은 27.51 mGy, B 그룹(3 point)은 21.39 mGy로 측정되었고 A 그룹에 비해 B 그룹에서 평균 22.26% 감소하였다. Bismuth 차폐체의 사용은 뇌혈관 중재적 시술 후 나타날 수 있는 일시적 탈모 및 기타 확률적 영향에 따른 방사선 장해를 감소시킬 수 있는 대안이 될 것으로 사료된다.