검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 1

        1.
        2022.05 구독 인증기관·개인회원 무료
        For transport containers for radioactive wastes, a drop test should be performed at a height of 0.3– 1.2 m on a rigid target depending on the weight as a normal condition in the regulation. In the drop test, a strain gauge is commonly used to measure the local strain, and the position of the strain gauges is determined by the experiences of the engineer in advance of the test. For this reason, the strains can be measured at only predetermined points. The DIC (Digital Image Correlation) method using highspeed cameras can be used to measure the change in strain over the region of interest. In addition, it is possible to measure effectively even in areas with high strain gradients that are difficult to measure with strain gauges. Therefore, the DIC method can measure the strain change according to time over the entire load path. When the drop test of the transport container is performed, the impact load is delivered through the lower corner fittings-corner posts-upper corner fittings-lids. In this study, white spray was sprayed on these main load path, and black speckles were created on the spayed surface to trace the rigid motion of speckles. The images taken during the drop test can be used to create a strain field over region of interest.