검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 1

        1.
        2022.05 구독 인증기관·개인회원 무료
        It is essential to provide a safe working environment for radiation workers. At a research reactor decommissioning site in Seoul (KRR1 & KRR2), radioactive waste drum disposal work is in progress. Before performing radiation work, it is necessary to determine the radioactivity of the waste drum to ensure safety. In this reason, we conducted a study to determine the detection efficiency of waste drums using the EXVol code. Determination of the full energy absorption peak efficiency (detection efficiency) is one of the important processes of the gamma-ray activation analysis. For the large voluminous gamma-ray sources like waste drum, the geometrical and attenuation effect should be considered. EXVol (Efficiency calculator for eXtended Voluminous source) code is a detection efficiency calculation code using the effective solid angle method. EXVol can calculate both coaxial and asymmetric structure. In addition, the introduction of a collimator made it possible to reduce the radiation intensity of a high radiation source. And it is possible to determine the precise detection efficiency according to the energy of a gamma ray at a specific position of the volume source. To verify the performance of the EXVol, a high resolution gamma spectroscopy system was constructed and measurement and analysis were performed. Measurements were performed on coaxial, asymmetric and collimated structures with standard point source, standard 1 L liquid volume source and HPGe detector. The measured results were compared with the calculation results of EXVol. The relative deviation of the measurement and calculation in the coaxial and asymmetric structures was 10%, and that of the collimation structure was 20%. Results can be available in analysis of waste drums’ radioactivity determination at a specific position.