검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 45

        1.
        2024.01 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        A force-free field (FFF) is determined solely by the normal components of magnetic field and current density on the entire boundary of the domain. Methods employing three components of magnetic field suffer from overspecification of boundary conditions and/or a nonzero divergence-B problem. A vector potential formulation eliminates the latter issue, but introduces difficulties in imposing the normal component of current density at the boundary. This paper proposes four different boundary treatment methods within the vector potential formulation. We conduct a comparative analysis of the vector potential FFF solvers that we have developed incorporating these methods against other FFF codes in different magnetic field representations. Although the vector potential solvers with the new boundary treatments do not outperform our poloidal-toroidal formulation code, they demonstrate comparable or superior performance compared to the optimization code in SolarSoftWare. The methods developed here are expected to be readily applied not only to force-free field computations but also to time-dependent data-driven simulations.
        4,300원
        8.
        2016.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        We estimate the fractal dimension of the ρ Ophiuchus Molecular Cloud Complex, associated with star forming regions. We selected a cube (v, l, b) database, obtained with J = 1−0 transition lines of 12CO and 13CO at a resolution of 22′′ using a multibeam receiver system on the 14-m telescope of the Five College Radio Astronomy Observatory. Using a code developed within IRAF, we identified slice-clouds with two threshold temperatures to estimate the fractal dimension. With threshold temperatures of 2.25 K (3σ) and 3.75 K (5σ), the fractal dimension of the target cloud is estimated to be D = 1.52–1.54, where P / AD/2 , which is larger than previous results. We suggest that the sampling rate (spatial resolution) of observed data must be an important parameter when estimating the fractal dimension, and that narrower or wider dispersion around an arbitrary fit line and the intercepts at NP = 100 should be checked whether they relate to rms noise level or characteristic structure of the target cloud. This issue could be investigated by analysing several high resolution databases with different quality (low or moderate sensitivity).
        4,000원
        17.
        2015.01 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        The effect of retained and reversed austenite on the damping capacity in high manganese stainless steel with two phases of martensite and austenite was studied. The two phase structure of martensite and retained austenite was obtained by deformation for various degrees of deformation, and a two phase structure of martensite and reverse austenite was obtained by reverse annealing treatment for various temperatures after 70 % cold rolling. With the increase in the degree of deformation, the retained austenite and damping capacity rapidly decreased, with an increase in the reverse annealing temperature, the reversed austenite and damping capacity rapidly increased. With the volume fraction of the retained and reverse austenite, the damping capacity increased rapidly. At same volume of retained and reversed austenite, the damping capacity of the reversed austenite was higher than the retained austenite. Thus, the damping capacity was affected greatly by the reversed austenite.
        4,000원
        18.
        2013.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        We present a multi-dimensional reduction method of the surveyed cube database obtained using a single- dish radio telescope in Taeduk Radio Astronomy Observatory (TRAO). The multibeam receiver system installed at the 14 m telescope in TRAO was not optimized at the initial stage, though it became more stabilized in the following season. We conducted a Galactic Plane survey using the multibeam receiver system. We show that the noise level of the first part of the survey was higher than expected, and a special reduction process seemed to be definitely required. Along with a brief review of classical methods, a multi-dimensional method of reduction is introduced; It is found that the ‘background’ task within IRAF (Image Reduction and Analysis Facility) can be applied to all three directions of the cube database. Various statistics of reduction results is tested using several IRAF tasks. The rms value of raw survey data is 0.241 K, and after primitive baseline subtraction and elimination of bad channel sections, the rms value turned out to be 0.210 K. After the one-dimensional reduction using ‘background’ task, the rms value is estimated to be 0.176 K. The average rms of the final reduced image is 0.137 K. Thus, the image quality is found to be improved about 43% using the new reduction method.
        4,000원
        20.
        2009.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        A method of estimating the lower bound of coronal magnetic field strength in the neighborhood of an ejecting plasmoid is presented. Based on the assumption that the plasma ejecta is within a magnetic island, an analytical expression for the force acting on the ejecta is derived. The method is applied to a limb coronal mass ejection event, and a lower bound of the magnetic field strength just below the CME core is estimated. The method is expected to provide useful information on the strength of reconnecting magnetic field if applied to X-ray plasma ejecta.
        4,000원
        1 2 3