검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 29

        21.
        2009.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        An experiment was carried out to evaluate the anchovy dryer performance using heat pump. We manufactured single stage refrigeration system using R22 and the dryer objects is frozen an anchovy. According to frame mobile method of the drying room inside divided at 3 drying rooms. After operating 13 hour machineries and accomplished a dryness experiment. The result which accomplishes an experiment, the dry condition which follows in frame movement of the drying room did not appear. According to the tray which is being put but in the frame the condition of anchovy dryness appeared different. It is concluded that the mean moisture evaporation rate is 60.7%, and the mean production of dryer an anchovy is 1.62 ton/day per dryer room.
        4,000원
        22.
        2009.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A system heat pump provides the benefits of comfort, energy conservation and easy maintenance. Recently, the system heat pump has been employed in small and medium-sized buildings. However, the performance data and control algorithm for system heat pump are limited in literature due to complicated system parameters and operating conditions. In the present study, the performance of a system heat pump with two indoor unit is measured by varying indoor loads, EEV opening, and compressor speed. In addition, the integral optimum regulator which includes MIMO control algorithm is proposed. The capacity modulation and optimum capacity for each indoor unit can be adjusted by utilizing the EEVs opening and compressor speed. The proposed scheme shows appropriate control performance at test conditions.
        4,000원
        23.
        2006.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        지열을 이용한 열펌프 시스템이 온실의 냉방과 과채류의 묘소질에 미치는 영향을 구명하였다. 온실 내 기온은 주간에는 차광구에 비해서 포그+차광구가 3~4℃ 낮았고, 야간에는 지열-펌프+차광구가 차광 및 포그+차광구에 비해 5~7℃ 낮았다. 오이, 고추 및 토마토 묘의 초장은 차광이나 차광+포그구에 비해 지열-열펌프+차광구가 가장 짧았고, 엽면적과 건물중은 지열-열펌프+차광구가 다른 처리에 비해 약간 작았다. 결과적으로 건묘지수는 지열을 이용하여 냉방을 한 지열+차광구는 포그+차광구 및 차광구에 비해 모두 높게 나타났다.
        4,000원
        24.
        2004.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 펌프 노즐이 부착된 잠수 선형의 유동에 관해 수치해석 결과를 보여준다. 이는 속도분포, 양력계수, 영각의 값을 갖는 펌프젯 노즐이 선체와 부착되었을 때와 부착되지 않았을 때의 종강도 모멘트 등의 값들을 계산한다. 선형의 속도 분포에 따른 노즐의 영향면적과 양력계수(변호의 특성요인) 종강도 모멘트, 영각에 따른 도함수 등을 보여준다.
        4,000원
        25.
        1999.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A fish pump makes very important roles in an automation system of an aquaculture farm, thus it has been used widely in order to transfer fishes from one place to the other place automatically. In spite of its significant roles, the efforts for developing performance and promoting efficiency of the fish pump are not sufficient yet. In this paper, a method which makes the fish pump automation system is suggested. Automation of the fish pump can be accomplished by using variable voltage and variable frequency inverter system including induction motors. Especially, very simple logic to generate Pulse width Modulation(PWM) wave to control induction motor efficiently and three steps speed control method to regulate liquid quantity of the fish pump simply are suggested. Owing to the simplifies speed control and PWM wave generation technique, a cheaper microprocessor, 80C196KC, than a digital signal Processor(DSP) can be used to operate control algorithm in induction motor systems for real time control Also, a new idea of remote control for the simplifies novel inverter system by Programmable logic Controller(PLC) without special output unit, digital to analog converter(D/A), is suggested in this paper. Consequently the function of reliability, availability and serviceability of the fish pump system are developed. It will be expected to contribute expanding of application of the fish pump in aquaculture farms because the system can reduce energy consumption and some difficulties according to manual operation prominently.
        4,000원
        26.
        2017.12 KCI 등재 서비스 종료(열람 제한)
        최근 송 ․ 배수시스템의 최적 펌프운영과 펌프 및 배수지의 적정용량 산정을 위한 다양한 연구가 진행되고 있다. 시설물의 적정 용량을 선정하기에 앞서 송수펌프 용량 및 배수지규모에 따른 시스템 비용(건설 및 운영비용)과 시스템 내 수질 변화를 분석하는 과정이 필요하다. 본 연구에서는 민감도 분석을 통해 송수펌프 용량과 배수지의 크기가 실제 시스템의 건설 및 운영비용, 그리고 시스템 전반의 수질에 미치는 영향을 분석하였다. 국내 대규모 지방상수도 시스템을 대상으로 분석을 실시하여 시설물 규모가 비용 및 수질에 미치는 영향을 명확히 파악하였다. 적용 네트워크의 경우, 시설물의 용량이 증가할수록 운영비용은 감소하지만, 설계비용은 증가하는 것으로 나타났으며, 이를 통해 비용최소화와 수질안정화를 동시에 만족하는 시설물의 적정용량 범위를 파악할 수 있을 것으로 판단된다.
        27.
        2017.04 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 고에너지 엑스선(6MeV)을 조사한 세포막 모델에서 K+-Na+ pump 시스템의 능동적 전달특성에 대하여 연구하였다. 이 실험에 사용된 세포막 모델은 Na+슬폰화 폴리스티렌-디비닐벤젠(polystyrene-divinylbenzene) 혼성 중합막을 사용하였다. 이온의 초기플럭스는 H+이온 농도의 증가와 함께 증가하였다. 이 실험의 조건을 pH 1.5-5, 온도 36.5℃로 하여 첫 번째, 방사선이 조사되지 않은 막에서 K+의 초기플럭스는 2.09x10-4-1.32x10-3mole/cm2·h이고 Na+의 초기플럭스는 7.09 x10-4-1.09x10-3mole/cm2·h으로 나타내었다. 두 번째, 방사선이 조사된 막에서 K+의 초기플럭스는 21.0x10-4-16.7x10-3mole/cm2·h이고 Na+의 초기플럭스는 62.0x10-4-20.6x10-3mole/cm2·h으로 나타내었다. 막의 K+/Na+선택도는 약 1.10이다. 조사된 막의 pH의 추진력은 조사되지 않은 막보다 약 9-20배 정도 유의성 있게 증가하였다. 세포막모델에서 K+-Na+의 pump 시스템의 능동적 전달특성이 비정상적이기 때문에 세포장해가 세포에서 발현된다고 사료된다.
        28.
        2007.11 KCI 등재 서비스 종료(열람 제한)
        일반적인 도시 내배수시스템은 시설물과 운영방법으로 구분된다. 시설물은 관거, 수문, 배수펌프장 등으로 구성되며 운영방법은 펌프 및 수문운영으로 구성된다. 이러한 내배수시스템에서 유역의 유출 및 펌프 운영을 실시간으로 모의하고 배수효과를 고려할 수 있는 운영 모형은 펌프를 효과적으로 운영하기 위하여 필요하며, 이러한 실시간 운영 모형을 통하여 도시유역의 침수 위험을 감소시키기 위한 효율적인 펌프 운영 기법의 개발이 가능하다. 본 연구에서는 SWMM 5.0
        29.
        2002.03 KCI 등재 서비스 종료(열람 제한)
        준설작업 효율성은 장비의 형식, 준설토의 특성, 작업의 성격, 작업 시행 전.후에 이루어지는 측량작업 등에 의해 결정된다. 특히, 준설선의 위치제어와 준설지점의 수심 측량은 전체 공정의 효율성 결정에 중요한 인자가 된다. 우리나라 준설업체가 주로 보유하고 있는 펌프식 준설선은 연속작업이 가능하고, 타 기종에 비해 작업해역에서 탁도 발생이 적다는 장점이 있지만 제거되는 슬러리에 토사 함유량이 적고, 위치 정확도가 낮다는 큰 단점이 있다. 본 연구에서는 LADGPS, 조석관측시스템, 광센서 각도추출장치, GIS와 전자해도를 이용하여 4개의 하부시스템으로 구성된 펌프식 준설선 통합공정관리시스템을 개발하여 준설선 위치제어, 실재 굴착이 이루어지는 준설지점의 위치결정, 작업해역의 조위가 보정된 실시간 수심결정, 작업지시내용 및 작업성과를 기록하고 이들 모든 정보를 작업자 모두가 실시간으로 모니터링하고 제어하는 공정관리를 수행할 수 치도록 하였다. 이 시스템을 펌프식 준설선인 "은진PD-2"에 설치하여 운영하였으며, 기존의 작업방식과의 작업효율성 비교를 위한 작업성과 데이타는 아직 추출하지 못했지만 일부 유사한 하부시스템이 적용된 그라브 쿤설선 공정관리시스템의 효율성 분석결과에서 준설해역의 편평도가 45cm 이내로 양호하고, 작업기간을 227f 단축하였으며, 작업비용을 16.6% 절감된 것으로 나타났다.
        1 2