        1.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A series of tests was conducted for full-scale single-pylon asymmetric cable-stayed bridges using a system of multiple shaking tables. The 2-span bridge length was 28 m, and the pylon height was 10.2 m. 4 different base conditions were considered: the fixed condition, RB (rubber bearings), LRB (lead rubber bearings), and HDRB (high damping rubber bearings). Based on investigation of the seismic response, the accelerations and displacements in the axial direction of the isolated bridge were increased compared to non-isolated case. However, the strain of the pylon was decreased, because the major mode of the structure was changed to translation for the axial direction due to the dynamic mass. The response of the cable bridge could differ from the desired response according to the locations and characteristics of the seismic isolator. Therefore, caution is required in the design and prediction in regard to the location and behavior of the seismic isolator.
        4,200원
        3.
        2009.03 KCI 등재 서비스 종료(열람 제한)
        교량 지지용으로 사용되는 강재 케이블에 대한 장력측정은 교량 안전관리의 중요한 측정항목이다. 현재 케이블에 걸린 장력을 진동법과 로드셀로 측정하고 있으며, 최근에는 선진국에서 자기적 방식에 의한 장력측정 방법을 연구하여 이에 대해 여러 가지 결과물을 제공하고 있다. 그러나 아직 우리나라에서는 이에 대한 체계적인 연구가 수행되지 않고 있어 자기적 방식에 의한 장력측정 연구를 시작하였으며 장력측정 정밀도 향상을 위해 연구하고 있다. 자기적 방식의 장력측정에서 강재 케이블 내의 온도와 자기장에 대한 영향을 검토해야 한다. 금번 논문에서는 온도에 따라 장력센서의 출력특성을 시험하였고 주어진 자기장에서 온도보정계수를 도출하였으며 시험실 내의 장력측정 시스템에 보정계수를 적용하여 케이블 장력에 따른 장력센서의 출력특성에 대한 시험 결과를 분석하고 평가하였다.