        1.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The heat transfer characteristics of forced convection according to the geometric shapes with four rectangular blocks in a horizontal PCB channel was analyzed numerically using SST (Shear Stress Transport) turbulence model. As the boundary condition for CFD (Computational Fluid Dynamics) analysis, the inlet temperature and air velocity were respectively 300 K and 3.84 m/s and the heat flux of the block surface was 358 W/㎡. The shape factors of block were width, height, spacing and channel entrance height. As the results, the heat transfer rate was decreased as the width ratio (x/h) was increased, while it was increased as the height ratio (h/x) is increased. Also as the block spacing ratio (s/x) was increased, the heat transfer effects was not significantly affected. And as the channel entrance height ratio (H/x) was increased, the heat transfer performance was decreased.
        4,000원
        2.
        2010.09 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        고준위 방사성 폐기물 처분장의 경우 폐기물의 방사성 붕괴에 의해 열이 발생되며, 암반을 통한 열전달 에 의해 처분장 주변 환경이 변화됨으로써 처분장의 안전성에 영향을 미칠 수 있다. 그러므로 지하 처분장 대기의 열전달계수를 결정하는 것은 매우 중요하다. 이에 본 연구에서는 Korea Atomic Energy Research Institute Underground Research Tunnel (KURT)에서 내부 환경 인자들의 측정을 통해 강제대류시 열전달계수를 산정하였다. 실험을 위해 KURT 내 히터구간의 막장 벽면에는 길이 2 m, 용량 5 kw의 히터를 삽 입하여 암반 내부를 90℃로 가열하였고, 외부와 연결된 급기용 팬에 의해 신선한 공기를 공급하였다. 연구 결과, 외부공기 공급 후 히터구간 대기의 기류속도는 평균 0.81 m/s로 측정되었고 레이놀즈수는 약 310,000 340,000의 값을 나타냈다. 그리고 강제대류조건에서 히터구간 내 계절별 열전달계수는 각각 여 름철 7.68 W/m2·K와 겨울철 7.24 W/m2·K의 수치를 나타냈다.
        4,200원