검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 1

        1.
        2013.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Local Nusselt number and temperature field distribution within the compound duct with gap have been measured. Measurement of air and wall temperature span a range of gap width from 2mm to 6mm. Also, the Reynolds number is variated from 20,000 to 40,0000. In order to observe the correlations between gap width and turbulent heat transfer, the present measurement has tried to verify the enhancement effect of heat transfer when a gap exists within the compound channel. From this measurement, we could see that the pulsating flow has generated a strong turbulent flow mixing within the compound channel. And the turbulent flow mixing in the pulsating flow plays an effective role of enhancing the Nusselt number by making the fluid temperature uniformly within the compound channel.
        4,000원