검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 6

        1.
        2013.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Local Nusselt number and temperature field distribution within the compound duct with gap have been measured. Measurement of air and wall temperature span a range of gap width from 2mm to 6mm. Also, the Reynolds number is variated from 20,000 to 40,0000. In order to observe the correlations between gap width and turbulent heat transfer, the present measurement has tried to verify the enhancement effect of heat transfer when a gap exists within the compound channel. From this measurement, we could see that the pulsating flow has generated a strong turbulent flow mixing within the compound channel. And the turbulent flow mixing in the pulsating flow plays an effective role of enhancing the Nusselt number by making the fluid temperature uniformly within the compound channel.
        4,000원
        2.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the present study, we developed optimal heat supply algorithm which minimizes the heat loss through the distribution pipe line in group energy apartment. Heating load variation of group energy apartment building in accordance with outdoor air temperature was predicted by the correlation obtained from calorimeter measurements of whole households of apartment building. Supply water temperature and mass flow rate were conjugately controlled to minimize the heat loss rate through distribution pipe line. Group heating apartment located in Hwaseong city, Korea, which has 1,473 households divided in 4 regions, was selected as the object apartment for verifying the present heat supply control algorithm. Compared to the original heat supply system, 10.4% heat loss rate reduction can be accomplished by employing the present control algorithm.
        4,000원
        3.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Ground source heat pumps are clean, energy-efficient and environment-friendly systems. Although the initial cost of ground source heat pump system is higher than that of air source heat pump, it is now widely accepted as an economical system since the installation cost can be returned within an short period of time due to its high efficiency. In the present study, performances of ground source compound hybrid heat pump system applied to a resort building are simulated. The system design and operation process appropriate for the surrounding circumstance guarantee the high benefit of the heat pump system applied to a resort building. If among several renewable energy sources, ground, river, sea, waste water source are chosen as available alternative energies are combined, COP of the system can be increased largely and hybrid heat pump system can reduced the fuel cost.
        4,000원
        4.
        2006.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        대립계 포도 비가림하우스에 부착된 일체형 방풍벽과 노지에 설치된 분리형 방풍벽의 구조 안전성을 설계풍속 30.9m·s-1와 50m·s-1 조건에서 각각 분석하였다. 비닐하우스 부착형 방풍벽의 경우, 방풍벽을 설치했을 때 방풍벽의 경사각이 측면부의 유동분포에 미미한 변화를 주어 측면부가 받는 풍압면적이 다소 감소하는 것으로 나타났으나 큰 차이를 보이지는 않았다. 그러나 구조강도 측면에서는 방풍벽 설치를 위한 부가적인 파이프 투입 효과로 약 11%정도 구조 안전성이 향상되는 것으로 분석되었다. 주기둥 간격이 3m인 분리형 방풍벽의 경우,대형 태풍수준인 50m·s-1에서 구조적으로 불안정한 것으로 나타났으며 분리형 방풍벽의 이론적 고찰 결과와 해석 결과와는 큰 차이를 보여 3차원으로 구성된 구조물의 2차원 모델 시 그 정확성에 한계가 있음을 알 수 있었다. 추후 분리형 방풍벽의 효용성을 증대하기 위하여 최적 파이프 규격 설정에 관한 세부적인 연구가 필요할 것으로 판단되며 비닐하우스 부착형 방풍벽의 경우, 태풍으로 인한 비닐하우스 피해 발생 시 정밀한 피해실태 조사를 통하여 분석 결과의 정확성을 향상시킬 수 있는 구조 안전성 분석 기법 개발에 관한 연구가 필요한 것으로 판단되었다.
        4,200원