Damped outrigger systems have been proposed as a novel energy dissipation system to protect tall buildings from severe earthquakes and strong wind loads. In this study, semi-active damping devices such as magnetorheological (MR) dampers instead of passive dampers are installed vertically between the outrigger and perimeter columns to achieve large and adaptable energy dissipation. Control performance of semi-active outrigger damper system mainly depends on the control algorithm. Fuzzy logic control algorithm was used to generate command voltage sent to MR damper. Genetic algorithm was used to optimize the fuzzy logic controller. An artificial earthquake load was generated for numerical simulation. A simplified numerical model of damped outrigger system was developed. Based on numerical analyses, it has been shown that the semi-active damped outrigger system can effectively reduce both displacement and acceleration responses of the tall building in comparison with a passive outrigger damper system.
PURPOSES: The purpose of this study is about noise which is generated from roads and is consist of irregular frequency variation from low frequency to various band. The existing methods of noise reduction are sound barrier that uses insulation material and absorbing material or have applied passive technology of noise reduction by devices. The total frequency band is needed to apply active noise control.
METHODS: In this study applies to the field of road traffic environment, signal processing controller and various analog signal input/output, the amplifier module is based on parallel-core embedded processor designed. DSP performs the control algorithm of the road traffic noise. Noise sources in the open space performance of evaluation were applied. In this study, controller of active signal processor was designed based on the module of audio input/output and main controller of embedded process. The controller of active signal processor operates noise reduction algorithm and performance tests of noise reduction in inside and outside environment were executed.
RESULTS : The signal processing controller with OMAP-L137 parallel-core processors as the center, DSP processors in the active control operations dealt with quickly. To maximize the operation speed of an object and ARM processor is external function keys and display for functions and evaluating the performance management system was designed for the purpose of the interface. Therefore the reduction of road traffic noise has established an electronic controller-based noise reduction.
CONCLUSIONS : It is shown that noise reduction is effective in the case of pour tonal sound and complex tonal sound below 500Hz by appling to Fx-LMS.
The researches related to active control systems utilizing superelastic shape memory alloys (SMA) have been recently conducted to reduce critical damage due to lateral deformation after severe earthquakes. Although Superelastic SMAs undergo considerable inelastic deformation, they can return to original conditions without heat treatment only after stress removal. We can expect the mitigation of residual deformation owing to inherent recentering characteristics when these smart materials are installed at the part where large deformation is likely to occur. Therefore, the primary purpose of this research is to develop concentrically braced frames (CBFs) with superelastic SMA bracing systems and to evaluate the seismic performance of such frame structures. In order to investigate the inter-story drift response of CBF structures, 3- and 6-story buildings were design according to current design specifications, and then nonlinear time-history analyses were performed on numerical 2D frame models. Based on the numerical analysis results, it can be comparatively verified that the CBFs with superelastic SMA bracing systems have more structural advantages in terms of energy dissipation and recentering behavior than those with conventional steel bracing systems.
본 연구에서는 풍진동제어를 위한 제어기 설계에 있어서 시스템식별에 기반한 모델의 차수 축소가 미치는 영향을 검토하였다. 실제 제어기 설계에 있어서 구조해석 모델이 이용될 수 없고 시스템식별이라는 중간과정을 거쳐서 얻어진 모델이 적용됨을 반영하여 원모델을 대상으로 풍하중에 대한 시간이력해석을 수행하고 이를 기초로 시스템식별을 수행하였다. 시스템식별을 통해 얻어진 상태방정식 모델에 모델축소 기법을 적용하였으며, 시스템식별에서 발생하는 측정잡음이 측정잡음이 모델의 정확도와 제어효과에 미치는 영향을 함께 검토하였다. 또한 모델축소 기법을 적용하여 얻어진 다양한 차수의 모델을 대상으로 제어기를 설계하고 성능을 비교함으로써 모델 차수가 제어효과에 미치는 영향을 검토하였다.
An active suspension system has an external energy source, from which energy is constantly supplied to the system for continuous control of the vehicle's motion. There are some control strategies. In the study, the reduced-order active suspension control strategy via the singular perturbation technique is applied to the half car model which has 4 DOF. The performance of the hydraulic active suspension system utilizing this control strategy is investigated and compared with those of the systems with the full-order state feedback control and the sky-hook damping control. Their performances are compared through the computer simulation in the time and the frequency responses, respectively. In the transient response analysis, the C-language program is used, and Matlab program tool is used in the frequency response analysis. It is shown that the reduced-order control strategy yields almost the same performance as that of the full-order state feedback control, and gives better performance than that of the sky-hook damping control, especially in ride quality.
사장교 케이블은 구조적으로 휨강성과 감쇠력이 작아 풍우에 의해 쉽게 유해진동이 발생한다. 이러한 풍우진동을 저감시키기 위한 효과적인 방법으로 부가댐퍼를 장착하여 케이블의 감쇠력을 증가시키는 제어시스템이 널리 사용되어왔다. 그러나 댐퍼를 케이블의 정착부 부근에 설치할 수밖에 없는 구조적 한계로 인하여 충분한 감쇠력을 발휘하기 어렵다. 그러므로 본 논문은 수동제어시스템 보다 효과적으로 풍하중에 의한 케이블 진동을 제어하기 위한 능동제어시스템을 제안하였다. 제안된 능동제어시스템은 케이블의 정착단에 베어링 장치를 장착하여 케이블 단부에서 횡방향 변위가 가능하도록 모델링 하였으며, 앵커리지 내부에 장착된 능동댐퍼를 이용하여 적절한 제어력을 제공하도록 하였다. 능동제어를 위하여 최적제어 이론을 이용 LQG 조정기를 설계하였으며, 수치해석은 실제 교량인 서해대교의 최장 케이블을 대상으로 하여 기존의 댐퍼 시스템과 수동, 능동 댐퍼 부착에 따른 케이블의 진동제어성능을 비교 및 분석하였다. 연구결과 제안된 능동제어시스템은 효과적으로 사장교 케이블의 진동을 저감시킬 수 있는 시스템임을 입증하였으며, 기존의 부가댐퍼 시스템 보다 효과적으로 진동을 저감시킬 수 있을 것으로 사료된다.
이 논문에서는 소형 다층 구조물의 진동제어에 적용하기 위한 복합모드의 자기유변유체(MR) 감쇠기를 개발하였다. 우선, 도식적으로 전단, 유동, 복합모드 MR감쇠기의 형태를 설계조건과 함께 표현하였고, 각각의 모드에 대하여 자기장에 따른 감쇠력을 예측하기 위한 해석모델을 유도하였다. 다음으로 적당한 크기의 복합모드 MR감쇠기를 제작하고 자기장에 따른 감쇠특성을 시간영역에서 평가하였다. 마지막으로 지진하중을 받는 소형구조물에 제작된 MR감쇠기가 준능동 제어기로 제어하였을 때의 성능을 수치적으로 평가하였다.
다양한 지진 규모 및 주파수 특성을 가지는 지반운동에 대하여 사장교에 장착된 준능동 제어시스템의 제어효과를 분석하고 비용효율성을 평가하였다. Dyke 등에 의하여 제시된 벤치마크 사장교 제어문제에 준능동 제어시스템을 설계하였으며, LQG 최적제어기에 기반한 bi-state 제어방법을 적용하였다. 제어시스템의 비용효율성은 제어시스템을 장착하지 않은 교량의 생애주기 비용에 대한 제어시스템을 장착한 교량의 생애주기비용의 비로서 정의하였으며, 손상비용 규모와 준능동 제어장치의 가격을 매개변수로 하여 그 변화에 따른 비용효율성 평가를 수행하였다. 분석 결과, 제어시스템의 경제적 효율성은 준능동 제어장지의 가격에 크게 민감하지 않은 반면, 손상비용 규모에 따라 민감하게 변화하였다. 또한 중진규모의 연약지반과 강진규모의 견고한 지반에 해당하는 지반운동에 대하여 준능동 제어시스템의 비용효율성이 높은 것으로 평가되었다.
본 연구에서는 수동, 능동, 반능동 및 복합 시스템과 같은 다양한 제어시스템의 효율성을 미국토목학회에서 제시한 지진하중을 받는 첫번째 벤치 마크 사장교을 이용해 조사하였다. 이 벤치마크 문제는 2003년 완공 예정으로 미국 Mississippi주에 건설중인 Bill Emerson Memorial교를 대상 구조물로 고려하였다. Bill Emerson Memorial 교는 New Madrid 지진구역에 위치하고 Wississippi 강을 횡단하는 주요 교량이라는 점 때문에 설계 단계에서부터 내진설계가 고려되었다. 사장교의 상세한 설계도면에 기초해 교량의 복잡한 거동을 나타낼 수 있는 3차원 선형모델과 각 제어시스템의 성능을 평가하기 위한 18개의 평가기준이 개발되었다. 본 연구에서는 네 종류의 수동제어 시스템, 한 종류의 능동제어 시스템, 두 종류의 반능동제어 시스템 밑 세 종류의 복합제어 시스템이 고려되었다. 수치해석 결과 모든 제어시스템은 지진하중을 받는 벤치마크 사장교의 응답을 감소시켰다. 그러나, 수동제어 시스템의 경우에는 뛰어난 제어성능을 얻기 위해서 다른 제어시스템에 비해 커다란 제어력을 필요로했다. 강인성에 관한 수지해석 결과에 따르면, 수동, 반능동 및 복합제어 시스템이 구조물 강성의 불확실성에 대해 강인함을 보였다. 따라서, 반능동 및 복합제어 시스템이 토목구조물과 같은 대형구조물의 실제 적용에 보다 적절하다.
현대의 고층건물들은 점차 유연해지고 경량화 됨으로 인하여 지진이나 바람과 같은 하중에 대하여 취약하다. 그러므로 이러한 하중에 대한 진동수준을 감소시키기 위하여 진동제어 시스템의 성능을 더욱 향상시킬 필요가 있으며 능동제어장치를 이용한 방법이 요구되고 있다 따라서 본 논문에서는 소형 진동대, 건물모델, 건물모델의 응답을 측정하는 센서, 신호처리 보드 그리고, 능동 질량 추진기로 구성된 능동 진동제어 시스템을 구축하였으며 이러한 개별 시스템들의 동적 특성을 실험적인 방법으로 조사하였다 또한 건물모델에 El Centro 지진을 가하여 능동 진동제어 시스템의 성능을 검증하였다,.
본 논문에서는 구조적으로 유연한 특성을 갖는 교량 구조물을 대상으로 외력에 의해 발생되는 진동을 실시간으로 제어하고자 준능동형 실시간 피드백 진동제어시스템을 구성하고, 이를 실험적으로 평가하였다. 여기서 진동제어를 위한 대상 교량 구조물은 서해대교를 약 1/200 크기로 규모화 하여 설계/제작한 모형 교량 구조물을 사용하였고, 실험실 여건을 고려해 규모화 된El-centro 지진파형으로 구조물을 가진하였다. 또한, 교량 상판 중앙지점에는 전자석이 채용된 전단형 MR 댐퍼를 수직방향으로 설치하여 발생된 진동을 제어하도록 하였고, 동시에 변위계 및 가속도계를 설치하여 구조물의 응답(변위, 가속도)을 획득하였다. 이때 진동제어의 실험은 크게 비-제어, 수동 on/off 제어, Lyapunov 안정론 기반 제어 그리고, Clipped-optimal 제어조건으로 구분하여 실시간 피드백 진동제어실험을 수행하였고, 이때 진동제어의 효과는 상판 중앙지점에 대하여 각 실험방법 별절대최대변위와 절대최대가속도 그리고, 인가전원의 소모량 등을 성능지수를 이용해 정량적으로 평가하였다. 진동제어실험의 결과로부터, Lyapunov 제어 및 Clipped-optimal 제어방법 모두 구조물의 발생 변위 및 가속도를 효과적으로 감소시켰으며, 특히 진동제어 시 요구되는 외부 인가전원의 소비를 크게 감소시킬 수 있음을 확인하였다. 최종적으로, 본 논문에서 구성한 준능동형 실시간 피드백 진동제어시스템은 교량 구조물에 발생된 진동을 제어 ․관리하기 위한 적극 ․ 효율적인 방법으로 활용될 가능성이 있음을 확인하였다.