PURPOSES : Fine dust significantly affects the atmospheric environment, and various measures have been implement to reduce it. The aim of this study is to reduce fine dust on roads by implementing porous pavements and a clean road system using the low-impact development technique.
METHODS : We conducted quality tests (draindown, cantabro loss rate, tensile strength ratio, dynamic stability, and indoor permeability coefficient tests) and performance evaluation (dynamic modulus and Hamburg wheel-tracking tests) on the porous asphalt mixture. Subsequently, we constructed a porous pavement road in a test bed and conducted a permeability test. In the test bed, we installed a nozzle, a water tank, and a fluid pump to water the roadside. After the clean road system was completely installed, we measured the concentration of fine dust before and after water was sprayed. Additionally, we conducted a total suspended solids (TSS) test to confirm the reduction in re-suspended dust.
RESULTS : All results from the quality test of the porous asphalt mixture satisfy the standards stipulated by the Ministry of Land, Infrastructure and Transport. Results from the dynamic modulus test show a low plastic deformation resistance but a high fatigue crack resistance. The results from the Hamburg wheel-tracking test satisfy the U.S. Department of Transportation standards. After the porous pavement was constructed, a permeability test was conducted, and the result satisfies the standard value. Using a particle counter, we measured the concentration of fine dust before and after water spraying, and results show 12.08% and 10.23% for PM10 and PM2.5 particles, respectively. The results from the TSS test show that after the initial water spray, almost all re-suspended dust are removed from a road. In unfavorable road conditions, almost all re-suspended dust are removed after a second water spray.
CONCLUSIONS : The results of all of quality tests performed on a porous asphalt mixture satisfy the standards. By applying the results to a test bed, the problem of securing water is solved. Using the clean road system, 12.08% and 10.23% of PM10 and PM2.5 particles are removed, respectively. The system removes PM10 particles (larger particles) more effectively compared with PM2.5 particles. IN the future, we plan to revise the maintenance plan such that the porous pavement can exhibit long-term performance. Because pipe freezing may occur in the winter, we plan to analyze the periodic maintenance plan of the porous pavement and develop a solution to mitigate the issue of freezing pipes in the winter.
A heat pump system using wasted heat from thermal effluent to supply the heating energy can reduce energy consumption and emissions of greenhouse gases by greenhouse facilities nearby. The Jeju National University consortium constructed a heat pump system using the thermal effluent from the Jeju thermal power plant of KOMIPO to provide with cool or hot water to greenhouse facilities located 2.5km from the power station. In this paper, the system configuration of the heat pump system was summarized, and the results of operations for demonstration of a heating performance carried out during the winter season in 2018 were investigated. Therefore, if the heating control by supplying thermal effluent to the facility greenhouse, it can contribute to reducing the energy cost and improving quality.
This research carried out an analysis on input cost and leakage reduction effect by leakage reduction method, focusing on the project for establishing an optimal water pipe network management system in the Taebaek region, which has been executed annually since 2009. Based on the result, optimal cost-benefit analysis models for water distribution network rehabilitation project were developed using DEA(data envelopment analysis) and multiple regression analysis, which have been widely utilized for efficiency analysis in public and other projects. DEA and multiple regression analysis were carried out by applying 4 analytical methods involving different ratios and costs. The result showed that the models involving the analytical methods 2 and 4 were of low significance (which therefore were excluded), and only the models involving the analytical methods 1 and 3 were suitable. From the result it was judged that the leakage management method to be executed with the highest priority for the improvement of revenue water ratio was installation of pressure reduction valve, followed by replacement of water distribution pipe, replacement of water supply pipe, and then leakage detection and repair; and that the execution of leakage management methods in this order would be most economical. In addition, replacement of water meter was also shown to be necessary in case there were a large number of defective water meters.
최근 기후변화에 따른 기상 이변으로 도심지내 집중호우, 이상 기온 등의 피해가 자주 발생함에 따라 대책수립에 관한 연구가 활발히 진행 중이다. 더욱이 도시화 및 시가화가 되어감에 따라 녹지의 감소, 포 장율의 증가 등으로 인하여 도달시간이 짧아지고 유출량이 증가하는 등 집중호우시 수해 발생 가능성이 증가하고 있다.(2010, 송창준)
본 연구에서는 기후변화로 인안 도심지내 집중호우에 대응하기 위한 방안으로 수문학적 시설인 LID(Low Impact Development)로 분류되는 배수성 아스팔트 포장을 적용하여 유출수 관리에 대한 분석 을 실시하였다. 저영향개발(Low Impact Development, LID)은 소규모 분산형의 자연 친환경적인 기법을 활용해 우수유출량 및 비점오염을 저감, 유출속도를 지연시켜 도시지역의 물순환 상태를 개발 이전에 가깝 게 유지하기 위한 기법으로 정의된다.(2011, 한우석) 미국의 PGDER(Prince George’s County, Maryland Department of Environment Resources)에서 시작하였으며, 강우 유출수 관리 및 도시개발 등으로 인한 유역 물 순환구조 개선을 위해 최근 주목받고 있는 단순하면서도 효과적인 방안이다.
환경적 측면어세 다양한 기능을 할 수 있는 LID기법 적용에 따른 효과를 알아보기 위해 전 세계적으로 SWMM 모형이 많이 사용되고 있지만 SWMM 모형 내 유량 및 수질에 따른 자동 보정 틀이 존재하지 않고 유역에 적합한 최적의 LID 기법 구조물의 설계 기준을 정할 수 있는 툴이 존재하지 않기 때문에 보다 효율적인 유역의 수문 보정 및 LID 기법 적용에 따른 효과 모의를 제공하지 않는다.(2012. 류지철) 따라서 본 연구에서는 LID 시설 중 하나인 배수성 아스팔트 포장에 대한 효과분석을 보다 정확하게 하기 위하여 DRIP (Drainage Requirements In Pavements)모형을 이용해 포장층의 설계를 통해 SWMM 모형으로 결과를 분석을 최종 목표로 하고 있다.
높은 포장온도는 아스팔트포장 소성변형의 주요인이나 소성변형을 줄이기 위한 방안으로서 포장온도를 줄이는 측면에서는 아직 많은 연구가 이루어지지 않은 실정이다. 본 연구에서는 소성변형결함을 줄이기 위한 하나의 대안으로, 온도저감 효과가 있는 것으로 알려져 있는 보수성 포장을 배수성 포장의 하부층에 설치한 포장의 공용특성을 연구하였다. 본 연구의 목적은 보수형 배수성 포장의 온도저감효과를 정량화하고, 포장가속시험(Accelerated Pavement Testing)을 이용하여 온도 저감에 따른 소성변형 감소효과를 확인하고, 정량화하는데 있다. 또한 추가적으로 보수성 포장의 상대강도계수를 분석하고, 일반 포장과 비교하여 설계법 적용시 포장두께를 줄일 수 있는지 여부를 알아보고자 하였다. 본 연구를 위해 보수형 배수성포장 2개 단면 및 일반 배수성 포장 1개 단면 등 총 3개 시험구간이 시공되었다. 히팅 및 살수를 일정주기로 실시하였으며 하중조건은 윤하중 8.2ton, 타이어 공기압 7.03kgf/cm2 타이어 접지면적 610cm2이었다. 이 연구에서 포장체 온도저감효과는 중간층의 경우 6.6~7.9℃(평균7.4℃), 표층의 경우 7.9~9.8℃(평균 8.8℃)였으며, 이를 통해 포장표면의 소성변형 발생을 26% 감소시킬 수 있었다. 또한 탄성계수로부터 추정된 보수성 포장의 상대강도계수는 0.173으로 일반 밀입도 포장의 1.2배 정도였으며, 일반배수성 포장 구간에서는 표층, 중간층, 기층 모두 소성변형이 발생한데 반해 보수형 배수성 포장 구간에서는 표층에서 대부분의 소성변형이 발생된 것으로 나타났다.
본 연구에서는 조력발전소 배수갑문의 형상과 배치에 따른 방류능력을 해석하는데 3차원 수치모의가 효과적으로 이용될 수 있음을 보였다. 3차원 수치모형은 RANS를 지배방정식으로 하는 FLOW-3D 모형을 이용하였다. 본 연구결과 배수갑문의 방류능력은 물받이길이와 도류벽의 접근각도에 큰 영향을 받는 것으로 나타났다. 그리고 이의 개선 여부에 따라 이상의 방류량 차이가 발생하였다. 또한 방류량은 배수문과 수차구조물을 연결하는 구조물의 형상과 물받이 끝 사면