Structural insulated panels, structurally performed panels consisting of a plastic insulation bonded between two structural panel facings, are one of emerging products with a viewpoint of its energy and construction efficiencies. Of the SIPs, Cyclic test was conducted by two kinds of specimens: single panel and double panels. Cyclic test results, which were equivalent to static test results, showed that maximum load was 45.42kN, allowable shear load was 6.3kN/m. Furthermore the accumulated energy dissipation capability for double panels was as 2.3 times as that for single panel. From performance of structural tests, the allowable shear load for panels was suggested to be at least 6.1kN/m.
Cyclic test was conducted by two kinds of specimens : single panel and double panels. Cyclic test results, which were equivalent to static test results, showed that maximum load was 45.42kN, allowable shear load was 6.3kN/m. Furthermore the accumulated energy dissipation capability for double panels was as 2.3 times as that for single panel. From performance of structural tests, the allowable shear load for panels was suggested to be at least 6.1kN/m.
In this study the cyclic lateral loading tests were performed on the hybrid precast concrete panels that are interconnected by dry joints to emulate concrete shear wall cores for a mid-rise modular building. Test results show that it is necessary to improve the details of vertical reinforcement welded to the flange of C section member to increase the lateral resistance of hybrid precast concrete panels.
To improve the wet process of concrete core wall, which is one of lateral load resisting system in high-rise modular building, the new composite panel system is developed and its structural performance under lateral load is investigated analytically.