In this study, the types of thermal breakers applied to structures to prevent thermal bridges were identified. Condensation prevention performance was evaluated for apartment houses with standard floor structures to which a thermal breaker was applied. In addition, the effect of thermal cross-blocking was compared by calculating the total heat and equivalent U-value through the wall. (1) As a result of the evaluation of anti-condensation performance, when “가” grade insulation was applied, the surface temperature increased by about 1K due to the application of the thermal breaker. The TDR value increased by about 0.06 to 0.07. When "나" grade insulation was applied, the minimum surface temperature increased by about 1K, and the TDR value increased by about 0.05~0.06. (2) As a result of the evaluation of total heat and U-equivalent, it was possible to reduce the total heat by 38.5~44.9% and U-equivalent by 38.5~45.0% for the "가" grade insulation to which the thermal breaker was applied. In addition, the "나" grade insulation to which the thermal breaker was applied can reduce total heat by 38.9 to 43.6%, and reduce the Uequivalent by 38.9 to 43.7%.
도심지의 제한된 공간에서 대형 건축 지하구조물을 축조하기 위한 지하 굴토공사는 주변지반의 안정이 최우선 되어야 하며, 이를 위해서 흙막이 공사가 필수적으로 검토되어야 한다. 가설 흙막이 구조에서 응력부담재로 주로 사용되고 있는 H-Pile은 주열식 흙막이 벽체에서 지하외벽의 시공 이후에는 방치되므로 재료의 낭비를 초래하게 된다. 이를 개선하기 위하여 가설재인 H-Pile과 지하벽을 합성한 합성지하벽 공법이 개발되어 현재 많은 국내의 현장에 활용되고 있다. 본 연구에서는 지하합성벽의 전단내력을 평가하기 위하여 총 5개의 실험체를 제작하였다. 실험변수로는 전단연결재에 따른 합성율과 벽체 두께를 변수로 하여 실험을 실시하였으며, 기준식에서 제시하는 콘크리트 전단강도와 H-Pile의 전단강도를 실험값과 비교 분석하였다. 실험결과 합성율이 증가함에 따라 전단강도는 상승하지만 그 차이는 크지 않은 것으로 나타났다. 합성지하벽의 전단강도 산정시, 콘크리트 강재의 웨브 뿐만아니라, 강재플랜지의 기여도를 고려한 새로운 식을 제시하고 이를 이용한 계산결과와 실험결과를 비교한 결과 좋은 대응을 보이는 것으로 나타났다.