OTEC(Ocean Thermal Energy Conversion) system using the temperature difference between cooler deep and surface ocean waters is one of the renewable energy. But in Korea, OTEC system can not apply except in winter because surface sea water temperature is not enough. C-OTEC(Combined OTEC) system is that utilizes temperature difference between sea water and the condenser of power plants via working fluid. It can be a good alternative in the warm surface sea water for Mid-latitudes region like Korea. In this study, a marine survey using multi-beam echo sounder, single-beam echo sounder and sparker seismic wave is performed and sea water intake pipe line is proposed for the 10kW C-OTEC Pilot Plant.
본 연구에서는 poly(vinyl chloride) (PVC)가지형 공중합체 전해질과 헤테로폴리산(HPA)을 이용하여 유무기 합성 전해질막을 제조하였다. poly(vinyl chloride)-g-poly(styrene sulfonic acid) (PVC-g-PSSA)는 PVC의 이차 염소의 직접적인 개시를 이용한 atom transfer radical polymerization (ATRP)로 합성하였다. 이때, HPA 나노입자는 수소 결합을 통해 PVC-g-PSSA 가지형 공중합체와 결합하는 것을 FT-IR spectroscopy를 통하여 확인하였다. 전해질막의 수소이온 전도도는 HPA의 질량 분율이 0.3이 될 때까지 상온에서 0.049에서 0.068 S/cm로 증가하였다. 이것은 HPA 나노입자 고유의 전도도와 가지형 공중합체가 가지고 있는 술폰산의 강화된 산도 때문이라고 추정된다. 합습률은 HPA의 질량 분율이 0.45까지 증가할수록 130에서 84%로 감소하였다. 이것은 HPA나노입자와 고분자 메트릭스 사이의 수소 결합의 상호작용 때문에 물을 흡수하는 site의 수가 감소한 결과라고 볼 수 있다. 열중량 분석결과 HPA의 농도가 증가할수록 전해질막의 열적 안정성이 강화된다는 것을 알 수 있었다.
복합지형을 지나는 박리흐름(separated flows)들이 와도 이론에 의해 모델링 되었다. 흐름은 비회전성 및 비점성으로 가정하였으며, 선형 시어흐름에 대한 유선함수를 결정하기 위해 새로운 기법이 기술되었다. 지형지물의 형태로는 snow cornice과 backward-facing step을 정의하였으며, 이러한 지형지물의 후미에는 유체의 박리현상과 역류현상(reattachment)이 생긴다. 유체의 박리현상이 지형지물의 가장자리에 발생되게 하기 위해 점 와도를 흐름에 발생시켰고, 지형지물의 가장자리에 있는 뾰족한 부분을 완화하고 최대곡률 부근에서의 섭동운동에 중요한 박리흐름 발생지점의 구속조건을 없애기 위해 conformal mapping을 수정하였다. 와도 발생지점에서 와도를 평형으로부터 이동시키거나, 또는 임의의 섭동을 초기흐름에 가하는 방식으로 섭동을 가하여 비정상흐름을 발생시켰다. 박리지점의 풍상측에서 연속적으로 방출되고, 또한 bubble의 이차순환에 의해 변형된 물질의 궤적들이 수치적으로 적분되었으며, 시간에 대한 농도누적이 역류지점의 풍하측 고정된 지점에서 계산되었다. 본 연구에 사용된 모델은 방출물질의 확산형태와 간헐성을 제대로 다룰 수 있음을 알 수 있으며, 이산적인 방법에 의한 다중-와도모델 및 수치모델의 결과들과도 일치한다. 본 연구에 의하면, 박리 및 역류현상이 있는 유체의 흐름 속에 순환하는 bubble들의 비정상상태(unsteadiness)는 풍하측에서 대규모의 고농도 누적을 일으키는 주요 원인이다.
As prevailing synoptic scale westerly wind blowing over high steep Mt. Taegulyang in the west of Kangnung coastal city toward the Sea of Japan became downslope wind and easterly upslope wind combined with both valley wind and sea breeze(valley-sea breeze) also blew from the sea toward the top of the mountain, two different kinds of wind regimes confronted each other in the mid of eastern slope of the mountain and further downward motion of downlsope wind along the eastern slope of the mountain should be prohibited by the upslope wind. Then, the upslope wind away from the eastern slope of the mountain went up to 1700m height over the ground, becoming an easterly return flow in the upper level of the sea. Two kinds of circulations were detected with a small one in the coastal sea and a large one from the coast toward the open sea. Convective boundary layer was developed with a thickness of about 1km over the ground in the upwind side of the mountain in the west, while a thickness of thermal internal boundary layer(TIBL) from the coast along the eastern slope of the mountain was only confined to less than 200m. After sunset, under no prohibition of upslope wind, westerly downslope wind blew from the top of the mountain toward the coastal basin and the downslope wind should be intensified by both mountain wind and land breeze(mountain-land breeze) induced by nighttime radiative cooling of the ground surfaces, resulting in the formation of downslope wind storm. The wind storm caused the development of internal gravity waves with hydraulic jump motion bounding up toward the upper level of the sea in the coastal plain and relatively moderate wind on the sea.