검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 11

        1.
        2024.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, we address the issue of temperature uniformity in high-power antenna systems by proposing and analyzing various design strategies. Specifically, when there is significant spatial freedom in the internal coolant pathways of the cooling plate, a counterflow approach is implemented to achieve temperature uniformity. Conversely, in scenarios where spatial constraints exist, a differential fin area design is proposed to effectively manage heat distribution. Additionally, in cases where the design of coolant pathways is restricted and fin design is not feasible, we suggest minimizing temperature variations by adjusting the thermal conductivity of the carriers located beneath the heat-generating components. This comprehensive approach aims to enhance the thermal management of high-power antenna systems, ensuring improved system stability and performance.
        4,000원
        2.
        2022.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the load fluctuation of the main engine is considered to be a disturbance for the jacket coolant temperature control system of the low-speed two-stroke main diesel engine on the ships. A nonlinear PID temperature control system with satisfactory disturbance rejection performance was designed by rapidly transmitting the load change value to the controller for following the reference set value. The feed-forwarded load fluctuation is considered the set points of the dual loop control system to be changed. Real-coded genetic algorithms were used as an optimization tool to tune the gains for the nonlinear PID controller. ITAE was used as an evaluation function for optimization. For the evaluation function, the engine jacket coolant outlet temperature was considered. As a result of simulating the proposed cascade nonlinear PID control system, it was confirmed that the disturbance caused by the load fluctuation was eliminated with satisfactory performance and that the changed set value was followed.
        4,000원
        3.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 국내에 새롭게 도입하고자 하는 인터모달 자동화물운송 시스템을 구현하기 위한 터미널 플랫폼 시설의 온도하중에 따른 적정 신축이음 간격을 살펴보았다. 터미널 플랫폼의 적정 신축이음 간격 검토는 미국 F.C.C.(federal construction council)에서 제안한 식을 이용하여 지역별 온도변화에 따른 최대 신축이음 간격을 설정하고, 구조해석 프로그램을 통해서 산출된 최대 변위값과 건축구조 수평변위 제한값을 비교하였다. 적정 신축이음 간격은 온도변화로 인한 구조물 최대 변위량이 수평변위 제한값 이하가 되는 슬래브 길이로 선정하였으며, F.C.C 제안식을 통하여 산정한 지역별 최대 신축 이음 간격을 적용하여 구조물 최대 발생 변위를 살펴본 결과, 건축구조 수평변위 제한값 이내에서 발생될 수 있는 최대변위 값을 확인할 수 있었다.
        4,000원
        4.
        2011.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 포스트텐션 콘크리트 포장(PTCP: Post-Tensioned Concrete Pavement)과 줄눈 콘크리트 포장(JCP: Jointed Concrete Pavement)이 접속되는 터미널 조인트의 시공시 초기 줄눈 폭 설계에 대하여 연구하였다. PTCP와 JCP 사이의 줄눈 폭은 소음과 승차감에 직접 영향을 미치는 요소이다. 초기 설계 줄눈 폭이 지나치게 크면 소음과 승차감을 저하시키고, 줄눈 폭이 지나치게 작게 되면 온도 상승시 슬래브의 팽창과 블로우업 발생으로 압축응력이 과도하게 작용하여 줄눈부 파손을 야기할 수 있기 때문이다. 본 연구는 온도변화에 따른 터미널조인트의 줄눈 폭의 연구를 위하여 PTCP와 JCP가 시공된 동해고속도로 주문진현장에서 2010년 8월과 11월에 줄눈 폭 데이터를 측정하고 분석하여 최적의 줄눈 폭 설계방안을 제시하였다.
        4,000원
        6.
        2020.06 KCI 등재 서비스 종료(열람 제한)
        According to a NASA Goddard Institute for Space Studies report, temperatures have risen by approximately 1 °C so far, based on temperatures recorded in 1880. The 2003 heatwave in Europe affected approximately 35,000 people across Europe. In this study, a cooling fog, which is used in smart cities, was designed to efficiently reduce the temperature during a heatwave and its pilot test results were interpreted. A model experiment of the cooling fog was conducted using a chamber, in which nano mist spray instruments and spray nozzles were installed. The designed cooling fog chamber model showed a temperature reduction of up to 13.8 °C for artificial pavement and up to 8.0 °C for green surfaces. However, this model was limited by constant wind speed in the experiment. Moreover, if the cooling fog is used when the wind speed is more than 3m/s in the active green zone, the temperature reduction felt by humans is expected to be even greater. As a second study, the effect of cooling fog on temperature reduction was analyzed by installing a pilot test inside the Land Housing Institute (LHI). The data gathered in this research can be useful for the study of heat reduction techniques in urban areas.
        7.
        2013.11 KCI 등재 서비스 종료(열람 제한)
        국내 교량 설계에서 온도 하중에 대한 현재 LSD (한계 상태 설계법)는 다양한 교량 형식에 대한 동일한 기준을 적용하고 있다. 본 연구에서는 유효 온도를 산정하기 위해 실제 크기의 상판이 없는 강상자형거더교 시험체를 제작하였다. 1년동안 강상자형거더교모형의 18개 지점에서 온도데이터를 측정하였다. 측정된 데이터를 바탕으로 대기 온도에 따른 교량단면내 유효 온도를 산정 하였다. 유로 코드의 유효 온도와 비교할 때 실측 유효온도의 결과는 매우 유사한 상관 관계를 보였다. 따라서, 본 데이터를 기반으로 산정 된 유효 온도는 국내 교량설계에 온도 하중에 적합한 설계 기준을 제시하기 위한 기초 자료로 사용할 수 있다.
        8.
        2013.04 서비스 종료(열람 제한)
        A present LSD(limited state design) code for bridge temperature load have applied a uniform standard for various bridge type. In this study, in order to acquire the calculation effective thermal, a steel box girder bridge section specimen with real size dimension was manufactured. And over a year, the temperature data were measured in the sections. Effective temperature within the cross section according to atmospheric temperature were calculated by this experiment data. The analyzed results was very similar correlation when compared with the effective temperature of the Euro Code. Therefore, the effective temperature which calculated based on the present data could be used as the basic data in order to present to the appropriate design criteria for the thermal loads on the domestic bridge design
        9.
        2013.04 서비스 종료(열람 제한)
        In this study, for estimation of accurate thermal loading for design and analysis of civil engineering structures analyzed the daily average temperature data which have been observed over the past 50 years by korea meteorological administration. Through statistical analysis of climatic data, presented basic data on the changes in the temperature of domestic unique for the design and analysis of civil engineering structures.
        10.
        2012.02 서비스 종료(열람 제한)
        토목구조물의 설계와 시공에 있어서 온도변화는 매우 중요한 요소 중 하나이다. 따라서 토목구조물의 설계 및 해석에 있어서 물성변화 특성을 고려한 대표적 기후조건에서 각각의 재료의 물성치를 적용하여, 설계 또는 구조해석을 실시하여야 한다. 본 연구에서는 토목구조물의 설계 및 해석 시 정확한 온도하중 산정을 위하여 기상청의 기후데이터를 이용하여 국내 대표 도시를 선정하여, 각 도시의 기상관측소 최대 30년(1982~2011) 기간의 일평균온도 데이터를 분석하였다. 각 데이터 값의 통계적 분석을 통하여 토목구조물 설계 및 시공에 있어 고려할 수 있는 최대/최소 온도 변화 값 및 국내 고유의 온도 변화에 관한 기초 자료를 제시하였다.
        11.
        2011.06 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 온도와 습도 및 냉·난방을 조절하여 건물 내의 쾌적한 환경을 제공하기 위한 승압쵸퍼와 PWM 전압 형 인버터로 구성된 태양광 발전 시스템을 제안하였다. 이 시스템은 안정된 변조를 위해 원칩 마이크로프로세서를 사 용하여 동기신호와 제어신호로 처리하였다. PWM 전압형 인버터와 위상의 동기를 위하여 계통전압을 검출하여 계통전압과 인버터 출력을 동상 운전하므로 잉 여전력을 연계할 수 있게 하였으며, 건물이나 병원 등 특정 건물의 온도 및 습도센서에 적용하여 양호한 동특성을 얻 을 수 있었다. 또한 시스템에 적용한 결과 고역률과 저고조파 출력을 유지함으로써 부하와 계통에 전력이 안정하게 공급될 수 있 도록 제어하여 좋은 결과를 얻을 수 있었다.