Seismic designs for Korean nuclear power plants (NPPs) under earthquakes’ design basis are noticed due to the recent earthquake events in Korea and Japan. Japan has developed the technologies and experiences of the NPPs through theoretical research and experimental verification with extensively accumulated measurement data. This paper describes the main features of the design-time history complying with the Japanese seismic design standard. Proper seed motions in the earthquake catalog are used to generate one set of design time histories. A magnitude and epicentral distance specify the amplitude envelope function configuring the shape of the earthquake. Cumulative velocity response spectral values of the design time histories are compared and checked to the target response spectra. Spectral accelerations of the time histories and the multiple-damping target response spectra are also checked to exceed. The generated design time histories are input to the reactor building seismic analyses with fixed-base boundary conditions to calculate the seismic responses. Another set of design time histories is generated to comply with Korean seismic design procedures for NPPs and used for seismic input motions to the same reactor containment building seismic analyses. The responses at the dome apex of the building are compared and analyzed. The generated design time histories will be also applied to subsequent seismic analyses of other Korean standard NPP structures.
In the event of an earthquake, non-structural components require seismic performance to ensure evacuation routes and to protect lives from falling non-structural components. Accordingly, the seismic design code proposes horizontal force for the design and evaluation of non-structural components. Ground motion observed on each floor is affected by a building's eigen vibration mode. Therefore, the earthquake damage of non-structural components is determined by the characteristics of the non-structural component system and the vibration characteristics of the building. Floor response spectra in the seismic design code are estimated through time history analysis using seismic waves. However, it is difficult to use floor response spectra as a design criterion because of user-specific uncertainties of time history analysis. In addition, considering the response characteristics of high-rise buildings to long-period ground motions, the safety factor of the proposed horizontal force may be low. Therefore, this study carried out the horizontal force review proposed in the seismic design code through dynamic analysis and evaluated the floor response of seismic waves considering buildings and predominant periods of seismic waves.
건축구조물의 비선형 지진응답해석에서 입력지진동은 구조물의 탄소성 지진응답을 좌우하는 중요한 요소이다. 지진동파형은 지진발생과 전파경로에 따른 여러 가지 인자에 의해 그 특성이 결정되기 때문에 구조물의 지진응답해석에서 일반성을 갖는 입력지진동을 선정하는 것은 매우 어려운 문제이다. 본 논문은 내진설계용 스펙트럼에 대응하는 인공지진동파형을 작성한 후, 작성된 인공지진동에 대한 탄소성 응답스펙트럼 특성을 분석한 것이다. 여기서 작성된 인공지진동파형은 과거의 지진에서 얻어진 기록지진동파형을 이용하여 기록지진동과 동일한 위상각을 가지며, 감쇠정수 h=5%일 때의 내진설계용 스펙트럼과 거의 일치하도록 작성되었다. 작성된 인공지진동은 원 기록지진동과 동일한 위상각을 가지며, 주기 T=0.02{\sim}10.0sec 범위에서 설계용 스펙트럼과 매우 근접하게 작성되었다. 인공지진동을 입력한 1자유도계의 탄성 및 탄소성 지진응답해석을 수행하여 탄소성 응답스펙트럼 및 탄소성 응답특성을 분석하였다. 본 논문에서 작성된 인공지진동은 건축구조물의 탄소성 지진응답해석용 입력지진동으로 충분히 타당성이 있다고 사료된다.