In this study, a method of leakage detection was proposed to locate leak position for a reservoir pipeline valve system using wavelet coherence analysis for an injected pressure wave. An unsteady flow analyzer handled nonlinear valve maneuver and corresponding experimental result were compared. Time series of pressure head were analyzed through wavelet coherence analysis both for no leak and leak conditions. The leak information can be obtained through either time domain reflectometry or the difference in wavelet coherence level, which provide predictions in terms of leak location. The reconstructed pressure signal facilitates the identification of leak presence comparing with existing wavelet coherence analysis.
If sewage flows for an extended time at low velocities, solids may be deposited in the sewer. Sufficient velocity or tractive force should be developed regularly to flush out any solids that may have been deposited during low flow periods. This study aims to evaluate the periods (T) during which sewage flow greater than the minimum tractive force maintains on a spot in sewer pipe system with lower tractive force or lower velocity than expected in the design step, when a storage tank installed in a place upsteam pours water into the sewer. The effect to T of design factors of storage tank and sewer pipes was evaluated assuming the uniform flow in sewers. When the area of orifice in the storage tank is 0.062 ㎡(or 0.28 m diameter), the maximum T of 31sec was maintained using the usually used preset range of values of several design factors. As the horizontal cross section of storage tank and water depth of storage tank and roughness in sewers increase, T linearly increases. Also, T linearly decreases as the diameter of a sewer pipe increases. Although T gradually decreases as the sewer pipe slope decreases to around 0.005, T decreases sharply when the slope is less than 0.003.
본 연구의 목적은 저열 시멘트를 활용한 콘크리트와 고밀도 폴리에틸렌을 활용한 친환경 저수조를 평가하는 것이다. 친환경 저수조의 강도와 파괴모드를 평가하기 위하여 콘크리트와 고밀도 폴리에틸렌 복합체의 인장강도 시험, 다양한 종류의 콘크리트 수화열 실험, 다양한 혼화재를 활용한 수화열 실험 등을 수행하였다. 수행결과 전단키가 콘크리트와 고밀도 폴리에틸렌의 복합체로 거동할 수 있는 중요한 역할을 한다는 것을 규명하였고, ㄱ 타입의 전단키가 V 타입보다 40% 이상 인장강도를 증진시킨다는 것을 보여주었다. 연구결과 새로운 친환경 저수조는 기존의 콘크리트 저수조보다 안전성을 개선시키며, 보다 적용성과 활용성이 많은 것으로 기대된다.
This study tried to investigate and analyze the actual state such as the regional, classified, and material characteristics of the water quality in order to research the several factors by which the filtrated water of the total 250 cases can be polluted in the water tank. The 215 points (86%) clean the water tanks twice a year regularly and J-city has done the best job of cleaning the water tanks. The fifty points (20%) of the total 250 investigation points examine the water quality of the water tanks every year, however, the 175 investigation points (70%) do not execute the inspection of water quality. In the case of the regional characteristics in the water quality, the 23 points (46%) in H-county, the 17 points (34%) in S-county, and the 16 points (32%) in G-city are incongruent in the standard, and the incongruity ratio of the water quality in J-city is the lowest. The result of the classified incongruity shows that total coliforms were found at the 61 investigation points, mesophilic bacteria were found at the 27 points, and turbidity was found at the 12 points. In the case of the material incongruity, concrete was found at the 63 investigation points as the most distinguished factor, and FRP (fiberglass reinforced plastic) at the 23 points, SMC (sheet molding compound) at the 12 points, and stainless steel was found at the 2 points.