Nuclear power plants in Korea were designed and evaluated based on the NRC's Regulatory Guide 1.60, a design response spectrum for nuclear power plants. However, it can be seen that the seismic motion characteristics are different when analyzing the Gyeongju earthquake and the Pohang earthquake that has recently occurred in Korea. Compared to the design response spectrum, seismic motion characteristics in Korea have a larger spectral acceleration in the high-frequency region. Therefore, in the case of equipment with a high natural frequency installed in a nuclear power plant, seismic performance may be reduced by reflecting the characteristics of domestic seismic motions. The failure modes of the equipment are typically structural failure and functional failure, with an anchorage failure being a representative type of structural failure. In this study, comparative analyses were performed to decide whether to consider the inelastic behavior of the anchorage or not. As a result, it was confirmed that the seismic performance of the anchorages could be increased by considering the inelastic behavior of an anchorage.
In order to predict inelastic displacement response without nonlinear dynamic analysis, the equal displacement rule can be used for the structures with longer natural periods than the characteristic period, Tg, of earthquake record. In the period range longer than Tg, peak displacement responses of elastic systems are equal or larger than those of inelastic systems. In the period range shorter than Tg, opposite trend occurs. In the equal displacement rule, it is assumed that peak displacement of inelastic system with longer natural period than Tg equals to that of elastic system with same natural period. The equal displacement rule is very useful for seismic design purpose of structures with longer natural period than Tg. In the period range shorter than Tg, the peak displacement of inelastic system can be simply evaluated from the peak displacement of elastic system by using the inelastic displacement ratio, which is defined as the ratio of the peak inelastic displacement to the peak elastic displacement. Smooth hysteretic behavior is more similar to actual response of real structural system than a piece-wise linear hysteretic behavior such as bilinear or stiffness degrading behaviors. In this paper, the inelastic displacement ratios of the smooth hysteretic behavior system are evaluated for far-fault and near-fault earthquakes. The simple formula of inelastic displacement ratio considering the effect of Tg is proposed.
The researches related to active control systems utilizing superelastic shape memory alloys (SMA) have been recently conducted to reduce critical damage due to lateral deformation after severe earthquakes. Although Superelastic SMAs undergo considerable inelastic deformation, they can return to original conditions without heat treatment only after stress removal. We can expect the mitigation of residual deformation owing to inherent recentering characteristics when these smart materials are installed at the part where large deformation is likely to occur. Therefore, the primary purpose of this research is to develop concentrically braced frames (CBFs) with superelastic SMA bracing systems and to evaluate the seismic performance of such frame structures. In order to investigate the inter-story drift response of CBF structures, 3- and 6-story buildings were design according to current design specifications, and then nonlinear time-history analyses were performed on numerical 2D frame models. Based on the numerical analysis results, it can be comparatively verified that the CBFs with superelastic SMA bracing systems have more structural advantages in terms of energy dissipation and recentering behavior than those with conventional steel bracing systems.
지반조건은 구조물의 지진거동에 매우 큰 영향을 미치고 성능에 기준한 내진설계에 중요한 요소이다. 이 논문에서는 지진에 의한 지반의 비선형성을 포함한 지반의 비선형성이 구조물의 탄성지진거동에 미치는 영향을 지반 구조물 일괄해석 유한요소법과 지반의 비선형성을 구현하기 위해 Ramberg-Osgood 토질모델에 대한 근사선형 반복해석법으로 연구하였다. 연구는 말뚝기초의 유무를 고려한 주기가 변하는 선형 단자유도계에 지표에서 기록된 1940년 EI Centre지진을 적용하여 수행하였다. 연구결과에 의하면 연약지반의 비선형 특성 영향이 구조물의 탄성 지진거동에 매우 중요하곡 성능에 기준한 지반의 비선형성을 고려한 구조물의 내진설계가 필요하다는 것을 잘 보여주고 있다.
이 연구는 철근콘크리트 구조물의 비탄성 거동을 파악하고 합리적이면서 경제적인 내진설계기준의 개발을 위한 자료를 제공하는데 그 목적이 있다. 정학하고 올바른 내진성능의 파악을 위하여 비탄선 해석프로그램을 사용하였다. 사용된 프로그램은 철근콘크리트 구조물의 해석을 위해서 유한요소법을 이용하여 개발된 RCAHEST이다. 재료적 비선형성에 대해서는 균열콘크리트에 대한 인장, 압축 전단모델과 콘크리트 소에 있는 철근모델을 조합하여 고려하였다. 이에 대한 콘크리트 균열모델로서는 분산균열모델을 사용하였다. 또한, 횡방향 구속철근으로 인한 강도의 증가 효과를 고려하였다.
이 연구는 지진 시 철근콘크리트 교각의 비탄성 거동 및 연성능력을 해석적으로 파악하는데 그 목적이 있다. 재료적 비선형성에 대해서는 균열 콘크리트에 대한 인장, 압축, 전단모델과 콘크리트 속에 있는 철근 모델을 조합하여 고려하였다. 이에 대한 콘크리트의 균열 모델로서의 분산균열모델을 사용하였다. 두께가 서로 다른 부재간의 접합부에 단면강성이 급변하기 때문에 생기는 국소적인 불연속변형을 고려하기 위한 경계면 요소를 도입하였다. 또한, 축방향철근의 유무 및 그 양 등에 따른 구속효과를 적절히 표현할 수 있는 해석 모델을 개발하였다. 본 연구에서는 철근콘크리트 교각의 비탄성 거동 및 연성 능력의 파악을 위해 제안한 해석기법을 신뢰성 있는 연구자의 실험결과와 비교하여 그 타당성을 검증하였다.
본 논문은 에너지 분산장치의 일종인 점탄성 감쇠기를 설치한 건물의 거동에 관한 연구이다. 평상온도에서 뿐만아니라 높은 주변온도 하에서도 점탄성 감쇠기를 설치한 건물은 이를 설치하지 않은 건물에 비해서 구조응답이 현저히 감소함을 나타낸다. 감쇠기에 대한 실험에서 얻은 결과를 회귀분석하여 감쇠기의 동적특성을 산정할 수 있는 실험식을 유도한다. 감쇠기를 설치한 건물의 구조감쇠는 모드 변형에너지법과 유도된 실험식을 이용하여 성공적으로 예측할 수 있다. 또한, 점탄성 감쇠된 건물의 지진하중에 의한 동적 구조응답을 예측하기 위하여 수치모형해석을 수행한다. 수치모형해석의 결과는 실험결과와 잘 일치하는 것으로 나타나 일반적인 모드해석방법에 의해 점탄성 감쇠기를 설치한 건물의 동적거동을 정확하게 예측할 수 있음을 보여준다. 이러한 결과를 토대로, 점탄성 감쇠기를 설치한 건물에 대한 설계방법을 제시한다. 이 설계방법은 일반적인 건물의 설계에 감쇠비라는 설계요소를 추가함으로서 가능해진다.