PURPOSES : This study provides fundamental information on the temperature variations in tunnel structures during severe fire events. A fire event in a tunnel can drastically increase the internal temperature, which can significantly affect its structural safety. METHODS : Numerical simulations that consider various fire conditions are more efficient than experimental tests. The fire dynamic simulator (FDS) software, based on computational fluid dynamics (CFD) and developed by the National Institute of Standards and Technology, was used for the simulations. The variables included single and multiple accidents involving heavy goods vehicles carrying 27,000 liters of diesel fuel. Additionally, the concrete material characteristics of heat conductivity and specific heat were included in the analysis. The temperatures of concrete were investigated at various locations, surfaces, and inside the concrete at different depths. The obtained temperatures were verified to determine whether they reached the limits provided by the Fire Resistance Design for Road Tunnel (MOLIT 2021). RESULTS : For a fire caused by 27,000 liters of diesel, the fire intensity, expressed as the heat release rate, was approximately 160 MW. The increase in the carrying capacity of the fire source did not significantly affect the fire intensity; however, it affected the duration of the fire. The maximum temperature of concrete surface in the tunnel was approximately 1400 ℃ at some distance away in a longitudinal direction from the location of fire (not directly above). The temperature inside the concrete was successfully analyzed using FDS. The temperature inside the concrete decreased as the conductivity decreased and the specific heat increased. According to the Fire Resistance Design for Road Tunnel (MOLIT 2021), the internal temperatures should be within 380 ℃ and 250 ℃ for concrete and reinforcing steel, respectively. The temperatures were found to be approximately 380 ℃ and 100 ℃ in mist cases at depths of 5 cm and 10 cm, respectively, inside the concrete. CONCLUSIONS : The fire simulation studies indicated that the location of the maximum temperature was not directly above the fire, possibly because of fire-frame movements. During the final stage of the fire, the location of the highest temperature was immediately above the fire. During the fire in a tunnel with 27,000 liters of diesel, the maximum fire intensity was approximately 160 MW. The capacity of the fire source did not significantly affect the fire intensity, but affected the duration. Provided the concrete cover about 6 cm and 10 cm, both concrete and reinforcing steel can meet the required temperature limits of the Fire Resistance Design for Road Tunnel (MOLIT 2021). However, the results from this study are based on a few assumptions. Therefore, further studies should be conducted to include more specific numerical simulations and experimental tests that consider other variables, including tunnel shapes, fire sources, and locations.
Among the Fire Protection in the interior representative case are spray coat, board, Paint. Intumescent paint has been developed that price competitiveness manufactures and Fire-resistances certificate was verified by experiment. Recent three-hour fire resistance performance developed Intumescent paint is applied as a high-rise, and major structures designed according to the refractory needs to be more efficient. However, domestic and outside the thermal properties of Intumescent paint materials are not proposed. Meanwhile, Intumescent paint in fire is built char layer since the 500∼60 0℃ and middle layer is formed by the decuple intumescent char more then cover thickness at room temperature. It is cut temperature flow off to the steel surface. Nonetheless, Bond Strength of steel and paint deprive as the intumescent char increases. and then steel surface are exposed to flame instantaneously. In this study, intumescent char estimate according to structural parameter(Fire resistance, cover thickness, shape ratio).
Among the Fire Protection in the interior representative case are spray coat, board, Paint. Intumescent paint has been developed that price competitiveness manufactures and Fire-resistances certificate was verified by experiment. Recent three-hour fire resistance performance developed Intumescent paint is applied as a high-rise, and major structures designed according to the refractory needs to be more efficient. However, domestic and outside the thermal properties of Intumescent paint materials are not proposed. Meanwhile, Intumescent paint in fire is built char layer since the 500∼60 0℃ and middle layer is formed by the decuple intumescent char more then cover thickness at room temperature. It is cut temperature flow off to the steel surface. Nonetheless, Bond Strength of steel and paint deprive as the intumescent char increases. and then steel surface are exposed to flame instantaneously. In this study, intumescent char estimate according to structural parameter(Fire resistance, cover thickness, shape ratio).
본 연구는 온도 증가에 따른 압축을 받는 H형 강재의 플랜지와 웨브의 국부 및 전체좌굴응력 내화해석 프로그램 개발과 플랜지와 웨브가 항복파괴전에 국부좌굴이 일어나지 않을 한계 판폭두께비의 상관값을 구하는 프로그램을 개발하는 것이다. 고온에서의 강재의 응력-변형도 관계식은 EC3:Part 1.2를 근거로 하였으며, 비교, 검토를 위하여 영국 BS5950의 강재를 대상으로 온도 증가에 따른 압축을 받는 강재의 플랜지와 웨브의 파괴온도와 하중을 본 연구의 내화해석 프로그램으로 예측하였다. 본 연구는 좌굴 및 항복에 대한 내화해석 프로그램을 개발하는 것을 목적으로 하고 적용 예를 통하여 좌굴 및 한계 판폭두께비를 분석하고 개발 프로그램의 타당성을 검토하였다.
AQUA/AMSR-E 인공위성 자료를 활용하여 3차원 최적내삽 해수면온도 합성장을 생산하였고 시간평균장과 비교하여 문제점과 한계점을 기술하였다. 3-D SST 합성장은 북태평양 중앙부에서 전체적으로 0.05˚C 이하의 작은 오차를 보였으나, 위성 결측이 있는 연안에서는 0.4˚C 이상의 비교적 큰 오차를 유발하였다. 강한 강수나 구름으로 인한 결측이 있는 부분에서는 0.1-0.15˚C에 달하는 오차를 보였다. 시간평균장과 비교한 결과, 구름 부근의 화소에서는 해수면온도를 낮게 계산하는 경향이 있었으며, 해수면온도의 공간적 구배를 감소시키는 평활화가 전체적으로 나타났다. 적도 부근 저위도에서 OI SST는 실제 해수면온도에는 없는 불연속성을 만드는 경향이 있었고, 이는 OI 과정에서 사용한 윈도우의 크기와 해양 현상의 수평 규모가 위도에 따라 변화하는데서 기인하였다. 현상의 공간 규모의 척도인 로스비 내부변형 반경은 북태평양에서 O(1) 정도로 위도에 따른 공간적 변화가 큰 것으로 나타났다. 본 연구는 SST합성장 생산과정에 위도와 해수의 수직적 밀도 구조와 밀접한 관련이 있는 해양 현상의 수평적 규모의 시공간적 변동 특성을 고려해야 함을 제시한다.
원자로 용기의 온도-압력 한계곡선을 위하여 국내공동비교연구를 수행하였다. 국내 원전의 데이터를 이용하여 국내 각 기관에서 온도-압력 한계곡선 작성에 사용하고 있는 방법 및 기법을 비교하기 위하여 round robin 해석을 제안하였고 주어진 문제에 대하여 각 기관이 문제를 해석한 후 결과를 제출하여 이들을 분석함으로써 온도-압력 한계곡선 작성에 대한 표준 해석 자료를 만들어 추후 평가에 이용할 수 있도록 하였다.
핵분열로 인한 고온, 고압의 냉각수를 유지하는 원자로 용기는 원자로의 냉각 또는 가열시 압력에 의한 응력과 함께 열응력이 가해지고 원자로 벽의 온도변화에 따라 파괴인성치가 변화하기 때문에 임의의 결함이 존재할 경우 건전성 확보가 쉽지 않다. 따라서 가상결함이 성장하지 않도록 압력과 온도를 조정하면서 냉각 및 가열시킬 필요가 있다. 본 연구에서는 원자로 운전 중 냉각 및 가열시 안전하게 운전하기 위한 압력/온도 한계곡선을 구하는 절차에 필요한 이론을 조사하였고 이의 도출을 위한 해석과정을 전산화하였다. 국내원전 중 가장 오래된 고리 1호기에 대한 압력/온도 한계곡선을 다양한 냉각 및 가열률에 따라 설정하였고 이들 결과를 검토하였다.