In this article, improvement of heat screen failure for battle tank is proposed. The heat screen applied to protect a cam sensor from engine heat was cracked by vibrations generated in the engine. To solve this problem, the configuration of the heat screen was changed to a structure that can avoid engine vibration levels. The improved heat screen has first mode frequency at 4,000 RPM band outside the main operating range of the engine, and heat dissipation is at the same level as conventional heat screen. As a result, the improved heat screen secured reliability by improving vibration effects by approximately 163% while maintaining heat dissipation performance.