        1.
        2024.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order support the design support system of small and medium-sized shipbuilding companies that carry out designs using 2D CAD, this study developed a system that automatically calculates the cable length by extracting the Y-axis value expressed as text data in 2D CAD. By setting the equipment where the cable starts and ends, the essential route and the installation rate were checked so that the optimal route of the cable could be calculated. As a result, the value calculated based on the optimal route and length of the cable by extracting the data of 2D CAD through this study was the same as the value previously calculated by the actual user, and the installation rate was less than 130% so there was no problem with the on-site installation. In addition, it was confirmed that the cable length calculated through this was reduced by about 7% compared to the existing work.
        4,000원
        2.
        2024.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to prevent disconnection of the hydraulic pump EDV cable, this study judged the vibration generated by the pump as the greatest effect on disconnection, and confirmed the vibration effect. And it had a structure that was vulnerable to vibration because of the wire flow space inside the EDV cable connector. After applying the improved adapter, vibration analysis, excitation test, and bending strength test were performed to confirm the effectiveness of design change and improvement. As a result of vibration analysis, the amount of vibration was reduced by about 10 times compared to the existing product, and the strength increased by about 4 times in the bending strength test was confirmed to increase the effect of preventing disconnection due to vibration.
        4,000원
        4.
        2005.08 구독 인증기관 무료, 개인회원 유료
        In this study, the wind response characteristics of a transmission tower are investigated through stochastic analysis considering the dynamics of a transmission line, The assemblage of the transmission line and insulator are modeled as a double pendulum system connected to the SDOF model of the tower. It is observed that the background component of the overturing moment induced by the wind response of the transmission line has considerable portion in the total overtuming moment. Based on this observation, a rotational viscoelastic damper is proposed for the suppression of the transmission line response to reduce wind load on the transmission tower. To verify the effectiveness of the proposed damper, time history analysis is conducted for various wind velocities. From the result of the analysis, the proposed damper is proved to be effective in the reduction of the background component rather than the resonance component of the support reaction of the transmission line.
        4,000원
        5.
        2014.11 KCI 등재 서비스 종료(열람 제한)
        사장교 케이블의 손상은 사장교 전체의 안전에 가장 큰 영향을 주는 요인이 되므로 케이블의 손상에 대한 유지관리를 필수적으로 해야한다. 이러한 유지관리의 대표적인 방법으로 케이블의 고유진동수변화을 추적하는 방법이 있다. 지금까지 케이블의 고유진동수는 진동법에 의해 횡방향 진동으로 추정하여 왔으며 시스템인식기법은 반복법에 의한 민감도방정식으로 축방향강성을 추정하나 새그의 영향으로 종방향운동에 대한 고유진동수의 분포에 대한 연구가 필요하다. 이 연구에서는 종방향운동에 의한 고유진동수를 이용하여 손상을 추정함으로써, 종방향운동의 신뢰성을 향상시키는 새로운 방법을 제안하였다. 이 방법의 적용결과를 근사해인 유한요소해석결과와 비교하여 유사한 결과를 얻음으로써 제안된 방법의 신뢰성을 검증하였다. 따라서, 케이블손상과 고유진동수와의 관계를 분석한 결과는 손상률이 증가할수록 고유진동수는 낮게 나타났다. 따라서 케이블의 실측 고유진동수를 알 때 케이블손상과 고유진동수와의 관계식을 통해 케이블의 손상정도를 추정할 수 있으므로 케이블의 효율적인 유지관리가 가능하게 된다.
        6.
        2013.03 KCI 등재 서비스 종료(열람 제한)
        사장교 케이블은 초기 큰 인장력으로 축강성이 매우 크지만, 횡방향 휨강성은 약하다. 풍하중이나 교통하중은 케이블을 심각하게 진동시켜 사장교의 사용성에 부정적 영향을 끼친다. 그러므로 장대교량에 감쇠장치를 설치하는 진동 저감 계획이 절실히 요구된다. 마찰댐퍼는 교통하중이나 풍하중과 같은 동적하중이 작용하는 케이블 진동에서 진폭과 지속시간을 대폭 감소시킬 수 있는 효과적인 장치임을 알 수 있다. 케이블 진동은 댐퍼제작방법과 설치위치 및 형상에 따라 효율이 달라질 수 있다. 그럼에도 불구하고 본 실험연구의 마찰댐퍼 설치전 후 제진성능효과 분석결과는 향후 사장케이블의 진동을 저감시키는 기본 자료로 활용할 수 있다.