In this experiment, the error according to the measurement method was analyzed for the length, angle, radius of curvature, and diameter of the measurement system analysis using a profile projector device used in the field. One-way analysis was performed on each data tested 30 times using a statistical technique. Through the experiment, it was found that an error occurred in each data when measuring the angle according to the measurement method, and the null hypothesis that no error occurred when measuring the length, inside dia and radius was established.
채소내의 칼륨은 만성 신부전 환자에게 악영향을 주는 것으로 알려져 있다. 하지만 채소는많은 다른 영양 물질 또한 함유하고 있으므로, 이러한 환자들에게 채소의 섭 취는 불가피하다. 본 연구는 완전제어형 식물공장에서 신장환자들을 위해 적합한 저칼륨 상추 개발을 위해 수행되었다. 본 연구에 사용된 상추 품종은 ‘찰스’ 품종이 었다. 완전제어형 식물공장에서 정식 후 28일간 수행되었으며, 광 환경은 LED (W:R, 9:1), 일장 16시간, 200μmol·m-2·s-1 이었고 재배 온도, 상대습도와 이산화탄 소 농도는 각각 15-21oC, 65%와 600-650mg·L-1 이었다. 1차 실험에서 배양액은 수확 전 1주전과 2주전에 칼륨농도를 10%와 5%로 낮게 처리하였고, 이를 토대로 2차실 험의 처리는 수확 전 2주전 5%, 1% 낮춘 처리와 원수로 재배한 처리였다. 식물체 내의 다량원소 분석을 위해 수확 후 ICP 분석을 하였으며 생체중과 엽수를 측정하였다. 실험 결과 식물체 내 칼륨함량은 대조구에 비해 2주전 처리에서 통계적으로 유의하게 낮았다. 생체중과 엽수는 대조구와 처리구에서 유의적인 차이를 보이지 않았으나 처리구간의 유의적인 차이는 있었다. 신장환자들 의 채소섭취량을 고려했을 때, 저칼륨 상추 생산을 위한 적당한 칼륨농도 조성은 수확 2주전 1%와 5%로 낮춘 처리였다. 본 연구를 통해 양액 내 칼륨함량과 처리시리를 조절하여 신장환자를 위한 저칼륨 상추를 개발할 수 있었다.
Fiber reinforced polymeric plastic (FRP) materials have many advantages over conventional structural materials, i.e., high specific strength and stiffness, high corrosion resistance, right weight, etc. Among the various manufacturing methods, pultrusion process is one of the best choices for the mass production of structural plastic members. Since the major reinforcing fibers are placed along the axial direction of the member, this material is usually considered as an orthotropic material. However, pultruded FRP (PFRP) structural members have low modulus of elasticity and are composed of orthotropic thin plate components the members are prone to buckle. Therefore, stability is an important issue in the design of the pultruded FRP structural members. Many researchers have conducted related studies to publish the design method of FRP structures and recently, referred to the previous researches, pre-standard for LRFD of pultruded FRP structures is presented. In this paper, the accuracy and suitability of design equation for the local buckling strength of pultruded FRP I-shape compression members presented by ASCE are estimated. In the estimation, we compared the results obtained by design equation, closed-form solution, and experiments conducted by previous researches.