Finite element analysis is conducted for investigation of structure behavior of high strength concrete(HSC) column-normal strength concrete(NSC) slab connection according to aspect ratio(h/c). Analysis method is verified through comparison of experiment and analysis. As a result, regarding to the aspect ratio, the ultimate strength of column-slab connection decreased as the column dimension increased while the slab thickness did not influence on the ultimate strength of the connection.
This research is a part of a research program to verify the flexural shear behavior of circular reinforced concrete bridge columns with respect to longitudinal steel ratio and transverse steel ratio under cyclic lateral load. In this paper, describes mainly failure behavior of circular reinforced concrete bridge columns with respect to test variables.
본 논문은 기둥형상비를 실험 변수로 가지는 무량판 슬래브-기둥 접합부의 내진성능을 평가하는데 있다. 본 연구에서는 무량판 슬래브의 뚫림 전단파괴를 방지하기 위하여 본 연구와 병행하여 진행된 연구에서 개발된 연속 절곡된 전단보강근을 적용하였다. 기둥형상비에 따른 실험체는 각각 FIS1-05(0.5), FIS1- 10(1.0), FIS1-20(2.0) 이다. 실험체의 수평방향으로 정적 수평하중을 가력 하였으며, 중력하중비에 의한 일정 수직 하중을 적용하였다. 실험결과는 슬래브-기둥 접합부의 수평 변위 및 강도를 기준으로 평가하였다. 분석결과, FIS1-05, FIS1-20와 같은 장방형 기둥을 갖는 접합부의 성능이 FIS1-10와 같은 정방형 기둥을 갖는 접합부보다 우수한 것으로 평가되었다.
연구는 플랫 플레이트 구조에서 직사각형 외부기둥-슬래브 접합부의 뚫림전단강도에 관한 실험결과에 관하여 다룬다. 직사각형 기둥의 형상비 증가에 따른 뚫림전단거동을 평가하기 위해 위험단면의 길이를 일정한 값이 되도록 기둥 단면크기를 산정하고 총 8개의 실험체를 계획하였다. 두 수준의 콘크리트 압축강도(f'c=24, 40MPa)에 대하여 기둥단면의 형상비(βc=C1