검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2

        1.
        2010.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, in circumstantial situation it is recommended positively to utilize of EIFS(Exterior Insulating and Finishing System) as energy policy for economizing energy. But internal EPS insulators of EIFS are exterior panel of high fire risk, because of constituting of flammable materials to be fragile in fire. In this study, fire risk is assessed by experiment Con Calorimeter test and SBI(Single Burning Item) test. As the result of experiment, Con Calorimeter tests do not reach to capability standard of internal incombustible grade, and are assessed as low grade in SBI incombustible grade. Because EIPS is exterior material in buildings with high fire risk in spite of good efficiency, it is required rapidly to take measures to meet situation through various studies(for instance, adjusting law regulation, etc.) in the future.
        4,000원
        2.
        2013.11 서비스 종료(열람 제한)
        This study characterized PM and VOC emissions from cow dung combustion in a controlled experiment. Dung from grass-fed cows was dried and combusted using a dual cone calorimeter. Heat fluxes of 10, 25, and 50 kW/m² were applied. The concentrations of PM and VOCs were determined using a dust spectrometer and gas chromatography/mass spectrometry, respectively. PM and VOC emission factors were much higher for the lower heat flux, implying a fire ignition stage. When the heat flux was 50 kW/m², the CO₂ emission factor was highest and the PM and VOC emission factors were lowest. Particle concentrations were highest in the 0.23-0.3-μm size range at heat fluxes of 25 kW/m² and 50 kW/m². Various toxic VOCs including acetone, methyl ethyl ketone, benzene, and toluene were detected at high concentrations. Although PM and VOC emission factors at 50 kW/m² were lower, they were high enough to cause extremely high indoor air pollution. The characteristics of PM and VOC emissions from cow dung combustion indicated potential health effects of indoor air pollution in developing countries.