검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 7

        1.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to examine the risk of electrical fire in places where electric heat wires are used. In general, the use of electric heating wires is becoming more common and prevalent in a bid to prevent increasing damage caused by freezing and bursting in residential water pipes, factory pipes and irrigation pipes in vinyl greenhouse and a variety of heat wire products are available in market with legal safety requirements imposed on them. However, the widespread use of anti-freezing burst heat wire products has caused increasing incidents of fire, which often fail to be incorporated into statistics due to quick onsite extinguishing and insignificant damage although damage is gradually on the rise. Against this backdrop, this study aims to look into the possibility of ignition caused by electric heat wires and the mechanism of how it turns into catching fire through overheat and short circuit tests for anti-freezing burst electrical heat wires (hereinafter called the ‘heat wire’) and expects to serve as the basis for further observations and analyses on the cause of fire and the process of ignition in a scientific manner.
        4,000원
        2.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigated the smoke blocking and control systems for the safety of residents evacuation and for the prevention of smoke spread through the central corridor in the event of central corridor type of intelligent building fire. We offered additional ways of utilizing smoke ventilators and intake ventilation equipment and utilized CFD-based fire simulation program(FDS Ver.5.5.3) in order to analyze the effect. As a result, many differences in the smoke block effect, depending on the application of smoke ventilator and location of installation, was found. In addition, the result was found that larger effect was showed not in the case of application of smoke ventilator in central corridor only but application in fire room. The reason is that the smoke leakage is blocked primarily as air is flowed in the fire room through open door by operation of intake smoke ventilator in the public corridor and secondarily, the smoke leakage to the public corridor could be blocked as fire and smoke were released to the opened smoke ventilator continuously. Especially, the effect was maximized through complex interactions by applying smoke ventilator and intake ventilation equipment in corridor together rather than applying smoke ventilator and intake ventilation equipment independently. The proposed measure through this study shall be considered from architectural plan as one of ways for blocking from smoke spread to the central corridor in the central corridor type of intelligent building. In addition, flaws on regulation shall be established and supplemented.
        4,200원
        3.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        On this study, we extracted pending problem and controversial point from management of disaster such as terror for domestic massive performance and then, investigated countermeasure plan against disaster for massive performance through comparison and analysis between anti-disaster strategy of Korea and U.S. U.S are conducting security system actively for passenger of major facilities such as public institution. Nonetheless, In U.S that has the world’s best security system, serious affair such as 911 terror and Boston marathon terror are continued to happen. When considering domestic situation that North Korea and South Korea are antagonistic to each other, it is judged when it is high time to prepare for threat of terrorism. Accordingly, On this study, through analyzing of latest terror attacks in U.S and disaster risk in the nation, we analyzed in detail countermeasure plan classified as legislation, operation of security system, instilling a sense. As the result of this analyzing, using by flow-chart, we suggested domestic optimized disaster management system for massive performance. Consequently, we propose to establish systematized disaster management system such as preliminary survey of disaster influence for massive performance.
        4,000원
        4.
        2012.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, FDS fire simulation experiments and measured wind speed by applying the exterior installation portion for blocking the spread of the fire was investigated. As a result, aluminum composite panels installed in the lower and the upper part of the panel to remove all the lower side, and then the maximum wind speed 0.24 m/s and the upper side 0.58 m/s were measured. In the FDS, the measured wind speed difference air currents are approximately 3.7 times in 12 seconds, the occurrence of 17 seconds early moment wind 2.2 m/s was measured from. Before and after the fire occurred in early of the air velocity about 39 seconds was 3.5 times difference. Such air currents caused by the temperature of the building but also by the building height was found. Turbulent flame of fire by expanding the vertical extent of damage become greatly important factor. Therefore, through the exterior installation portion of the block that can delay the spread of fire is expected that this should be taken.
        4,000원
        5.
        2010.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, in circumstantial situation it is recommended positively to utilize of EIFS(Exterior Insulating and Finishing System) as energy policy for economizing energy. But internal EPS insulators of EIFS are exterior panel of high fire risk, because of constituting of flammable materials to be fragile in fire. In this study, fire risk is assessed by experiment Con Calorimeter test and SBI(Single Burning Item) test. As the result of experiment, Con Calorimeter tests do not reach to capability standard of internal incombustible grade, and are assessed as low grade in SBI incombustible grade. Because EIPS is exterior material in buildings with high fire risk in spite of good efficiency, it is required rapidly to take measures to meet situation through various studies(for instance, adjusting law regulation, etc.) in the future.
        4,000원
        6.
        2009.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Considering heat insulation and beautiful sight of construction, making use of exterior panels is increasing. Recently the exterior panels now are weak very much, and so in consequence of the weakness fire spreads rapidly. Compared with internal fire, external vertical fire spread rate goes rapidly and it is extensive in spread range, therefore it is dangerous very much. Accordingly, under present condition of poor standard of exterior panels, it is required to take measure to meet the appropriate situation. In this study, by making use of FDS(Fire Dynamic Simulation) program about external vertical fire of high rise building, fire behavior is searched by computer. It is important that realizing by computer fire modeling about external vertical fire must be included certainly in procedure of fire performance design in the future. In modeling program, FDS version 5 is available, and aluminium composite panel is applied in external panels. In this study, for realizing of actual fire condition, FDS is applied by details of fire scenarios considering influence of wind.
        4,000원
        7.
        2015.12 KCI 등재 서비스 종료(열람 제한)
        2014년 우리나라 선용품 시장의 규모는 5조 7천400억 원 정도로 추정되며, 대부분이 부산, 울산 등 경남권에서 이뤄지지만, 관련 업체가 400여 개나 난립해 대부분 평균 매출이 20억 원 미만으로 영세한 수준이다. 또한, 세계 해운항만산업의 불황과 중국을 비롯한 개발도 상국들의 저가 선용품의 생산 및 공급으로 인해 국내 선용품 업계의 전망은 그다지 밝지 않는 상황이다. 이에 본 논문에서는 선용품 산업의 활성화를 위한 방안 중 하나로 선용품 공동물류를 선택하였고, 공동물류를 운영함에 어떠한 요인이 중요한지에 대한 연구를 진행하였다. 선행 연구 고찰을 통해 공동물류 운영과 관련된 16가지 요인을 도출하여 AHP, IPA 기법을 활용해 분석 하였다. 분석결과 비용측면이 선용품 공동 물류를 운영하는 데 있어 가장 중요한 요인으로 나타났다.