검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 5

        1.
        2023.02 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        When exposed to different types of bacteria in the oral cavity, denture based resins are prone to bacteria attachment. The purpose of this study was to investigate the physical, biological, and antimicrobial properties of denture base resins coated with Peony extract (200, 400, and 600 μg/mL). Specifically, the surface properties (microhardness, contact angle, and color change of the coated specimens), cell cytotoxicity (measured using MTT assay), and antimicrobial activity (against S. mutans (Streptococcus mutans) and C. albicans (Candida albicans) using a growth inhibition assay) were evaluated. The polyphenol content was measured using ultraviolet-visible (UV-vis) spectrometry. The experimental groups (specimens coated with Peony extract) and a control group (specimens coated without Peony extract) were statistically compared using a one-way analysis of variance and Tukey’s post-hoc tests. No statistically significant differences in surface properties or cell cytotoxicity were observed, which demonstrated their biocompatibility. Conversely, a statistically significant difference in antimicrobial activity was observed between the experimental and control groups after 48 h. This confirms the antimicrobial activity of the denture base resin coated with Peony extract and demonstrates that it is a promising dental material for preventing stomatitis.
        4,000원
        2.
        2016.06 구독 인증기관 무료, 개인회원 유료
        Human mouth environment is known to include a variety bacteria, including Streptococcus spp., Staphylococcus spp., Actinomyces spp., Lactobacillus spp., Candida spp., Enterobacteriaceae, et al. Human oral microorganisms can cause dental caries, gingivitis, periodontitis, respiratory tract infection, and cardiovascular disease. Thus, right denture cleaning is essential to oral and general human health. The aim of this study was to evaluate the bactericidal effect of a sodium dichloroisocyanurate-based effervescent tablet (Aos Denti Germ, Aos Company, Chungbuk, Korea) against oral microorganisms. A total of 5 species Streptococcus spp. (Streptococcus anginosus, Streptococcus mitis, Streptococcus mutans, Streptococcus oralis, and Streptococcus sobrinus), Actinomyces oris, Candida albicans, and Escherichia coli were used in this study. All strains were exposed to the distilled water prepared with effervescent tablet. After the exposure, the mixture of strains and effervescent tablet was inoculated onto blood agar or MacConkey agar plate and cultured at 36℃. All strains were killed immediately on exposure to effervescent tablet. The results suggested that effervescent tablet could be used as an effective denture cleanser for dental hygiene.
        4,000원
        3.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적 : 본 논문은 임상적으로 정형화된 경추부 MR 검사에서 틀니 제거와 침 삼킴 등의 불수의적 구강 운동에 의한 움직임 인공물을 개선하기 위하여 구강 삽입 유도기구를 이용한 추가적인 검사 방법을 제안하고자 하였다. 대상 및 방법 : 2013년 12월 01일부터 2014년 1월 31일까지 경추부 질환으로 내원한 환자 중 틀니를 착용한 13명(남자: 7명, 여자: 6명, 평균 연령: 59±7.23세)을 대상으로 C-Spine 검사를 시행하였다. 대상 선정 시 폐쇄 공포증 환자, 진정제 사용 환자는 검사에서 제외하였다. 본 연구에 사용된 자기공명기기는 경추부 MR 검사에 최적화된 1.5T(Magnetom Avanto, Siemens, Germany)를 사용하였으며 고 신호 강도를 획득하기 위한 경추 전용 위상배열코일(Neck matrix coil)을 사용하였다. 실험 도구는 구강 삽입 유도 기구(Endo-piece, Vision, Korea)를 사용하였다. 실험 방법으로 대상에게 고정도구의 안정성과 검사에 관한 사항을 먼저 설명을 한 후 정상 체위앙와위(supine position)로 T₁-TSE-Sagittal, T₂-TSE-Sagittal, T₁-TSE-Axial, T₂-TSE-Axial을 획득하고 환자의 입에 구강 삽입 유도 기구를 삽입한 후 다시 T₁-TSE-Axial과 T₂-TSE-Axial을 검사하였다. 영상의 평가와 분석은 환자의 임상 소견과 판독 결과를 바탕으로 한 정성적 분석(qualitative analysis)과 SNR(signal to noise ratio)과 CNR(contrast to noise ratio)을 바탕으로 한 정량적 분석(quantitative analysis)을 사용하였다. 결 과 : SNR은 고정도구 삽입 전 T₁-TSE-Axial이 22.33±8.59, 고정도구 삽입 후 T₁-TSE-Axial이 25.21±7.93, 고정도구 삽입 전 T₂-TSE-Axial이 14.49±5.74, 고정도구 삽입 후 T₂-TSE-Axial이 16.61±6.72이었다. CNR은 T₁-TSE-Axial이 0.236±0.21이고 T₂-TSE-Axial이 0.219±0.22로 측정되었다. 정성적 분석 결과 고정도구 사용 전 T₂-TSE-Axial 에서 3.25±0.18점, 고정도구 사용 후 T₁-TSEAxial 영상이 3.95±0.14점을 나타내었다. 결 론 : 고정도구를 사용한 추가적인 검사기법의 적용으로 환자들의 불수의적 인공물이 저감화됨에 따라 영상의 대조도와 분해능이 향상되었고, 영상 판독과 질환의식별에도 기존 검사 기법에 비해 향상됨을 알 수 있었다. 특히 움직임 인공물로 인해 질환의 경계가 불분명했던 부분이 명확해 졌으며 업무의 질이 향상됨을 알 수 있었다.
        4,000원
        4.
        2003.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        4,000원