검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 3

        1.
        2018.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Vortex tubes are simple tubes that can separate hot and cold air from compressed air without any internal device configuration and are used in many industries. If the vortex tube with these advantages is applied to an air conditioning system, it will be free from the use of refrigerant. In this study, basic study on discharge flow rate and temperature separation characteristics was carried out by varying the number of generator nozzle hole in various shapes of the vortex tube according to the inlet pressure of the vortex tube. Experimental results show that as the number of nozzles increases, the discharge flow rate tends to decrease and the temperature separation characteristics were excellent in the number of nozzles 6~7.
        4,000원
        2.
        2013.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 단면변화를 고려한 수위-단면적 변화 및 평 균 유속-단면적 간의 상관관계를 분석하여 유량 산정 및 하천관리에 활용하고자 하였다. 수위에 따른 단면적 변화 는 SB-A 지점은 1.0 m, 1.9 m, SB-C 지점은 0.6 m, 1.8 m, CL-A 지점은 1.0 m, 1.8 m, OS-A 지점은 0.6 m, 2.0m에서 발생되었다. 이 중 첫 번째 변화는 평∙저수기에 해당되 고, 두 번째 변화는 홍수기 및 하천 좌∙우 안에 인위적 ∙자연적으로 형성된 둔치 등으로 판단된다. 수위-단면적 변화에 따른 관계식의 기울기는 지수형 0.5539~1.9013, 선형 9.040~52.544의 범위를 가진다. 기울기는 두 곡선 모두 고수위로 갈수록 증가하는 경향을 보인다. 평균유 속-단면적 변화의 관계는 지수와 직선의 방정식으로 지 수형 기울기와 상관계수는 각각 0.1182~0.8734, 0.22~ 0.86이며, 선형의 기울기와 상관계수는 0.0028~0.1032, 0.20~0.87로 분석되었다. SB-A, SB-C 지점의 저수위는 다른 수위보다 상관관계가 높게 산정되었는데, 이는 수위 구간이 좁고, 하천 단면적의 변화가 크지 않기 때문으로 판단된다. CL-A, OS-A 지점은 월류보의 영향으로 저수위 일 경우에 상관관계가 낮았다. 수위-단면적, 평균유속-단 면적의 상관관계 및 곡선식 등을 이용하여 하천 정비계 획 등의 수립에 활용할 수 있으며, 제외지의 단면적이 변 하는 지점의 유량 변화 등의 예측에 활용할 수 있을 것 이다.
        4,000원
        3.
        2013.02 KCI 등재 서비스 종료(열람 제한)
        Discharge data examine the process of hydrologic cycle and used significantly in water resource planning and irrigation and flood control planning. It makes high quality discharge data, they carry out research on standard and method of discharge measurement, and equipment improvement. Now various flow meters are utilized to make discharge data in Korea. However, accuracy of equipment and exprerimental research data from measurement are not enough. ADCP(Acoustic Doppler Current Profiler) have been introduced and utilized for flow measurements since the end of 1980’s. ADCP flow method is a formal method for flow measurement can easily applyd to relatively large rivers gradually recognized. This equipment can measure the non-contact three-dimensional velocity and water depth data very quickly and efficiently. Also, spatial and temporal resolution of the data is more accurate than any other flow measurement methods which measure flow rate by velocity - area measurement method. In this paper, the velocity is measured using various flow meter and verified the effectiveness by applying from the ADCP in Geum-river. Various flow meters which are med for discharge measurements are VALEPORT002 , FLOW TRACKER, PRICE AA and ADCP. The average of five times flow measurement result by ADCP was 10.412 ㎥/s, with a standard deviation of 0.68. The repeat test by ADCP and comparison between ADCP and other flow devices to verify the most import factor, flow measurement accuracy. In the result, repeat test of the ADCP showed similar values, flow values were similar to other velocity device results and the average error is 7.7%.