For safe and successful decommissioning, it is one of the most important procedures that establishing the goal and complying with regulations of which final status of decommissioned site and building. The dose criteria for cyclotron facilities should be established and applied to reuse the site and building, since building and component of a cyclotron facility have been activated by incident secondary neutrons from radioactive isotope processes (e.g. 18O(p,n)18F, etc.). Furthermore, appropriate approaches should be applied to demonstrate compliance with the dose criteria for reliability of reuse. It is of noted that U.S. NRC (Nuclear Regulatory Commission) has confirmed that the residual radioactivity which distinguishable from background radiation results in a TEDE (Total Effective Dose Equivalent) does not exceed 25 mrem (0.25 mSv) per year as radiological criteria for unrestricted use of not only nuclear power plants but also cyclotron facilities referred to 10 CFR Part 20.1402. In addition, U.S. NRC noted the two approaches (i.e. dose assessment methods and, DCGL and final status surveys) which can be applied for demonstrating compliance with the dose criteria of 10 CFR Part 20 and recommended DCGL and FSS approach based on advantages and disadvantages of the two approaches. In order to using DCGL and FSS approach, U.S. NRC suggested screening approach; using DandD Version 2 which assesses TEDE under ICRP 28 and site-specific approach; using all models or computational codes which approved by NRC staff. There are several foreign cases that release of cyclotron facilities after decommissioning (i.e. U.S. and Japan). U.S., for examples, there are two DCGL approach cases and one dose modeling case based on 25 mrem per year same as reactor facilities. The dose modeling case, however, which may not be really used in Korea because of its low applicability. On the other hand, Japan case did not establish any radiological criteria for site and building reuse such as DCGL and just confirm “no more contamination” which is all residual radioactivity is lower than MDC based on real survey. Japan case also may not be used in Korea since criteria of “no more contamination” is not clear and hard to apply for all sites. Considering regulations and criteria for site release and reuse in Korea, this study aims to suggest radiological criteria and the demonstration approach of compliance for decommissioning of cyclotron facilities based on Nuclear Safety Acts and NSSC notices.
최근 넓은 동적 범위 특성을 제공하는 평판 디텍터 개발을 바탕으로 의료보건 환경이 디지털화되고 있 는 현 시점에서 적절한 필터 두께의 재설정이 요구되고 있으나, 현 임상에서는 기존 아날로그 시스템에서 연구된 정보를 바탕으로 NCRP에서 제안한 권고 기준을 이용하고 있다. 이에 본 연구에서는 디지털방사선 촬영에서 알루미늄 필터를 이용하여 환자선량 최적화와 더불어 선량크리프의 최소화 가능성을 고찰하였다. 연구 결과, 알루미늄 필터의 두께를 증가함에 따라 유사한 선예도를 가지는 의료영상을 획득 시 피폭되는 피부입사선량을 최대 19.3% 저감할 수 있는 것으로 나타났으나, 영상학적 관점에서 중요한 해상력이 1.01 lp/mm의 큰 변화가 분석되었다. 이러한 해상력의 변화는 X선 빔 경화 현상으로 인하여 피사체에서 발생하는 산란선이 증가하기 때문으로 사료되며, 산란 열화 인자를 통하여 산란선량에 의한 영향이 증가하는 것 을 정량적으로 검증하였다. 하지만, 최근 개발되어 광범위하게 적용되고 있는 평판 디텍터는 방사선에 대한 민감도가 높고 넓은 동적 범위 특성을 가지므로 필터 두께에 따라 산란선의 비율에 대한 증가분과 대응 하여 적정한 해상력을 유지할 수 있을 것으로 사료되며, 더 나아가 피폭선량 저감을 통해 선량크리프를 최소화 할 수 있을 것으로 기대된다.