검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 5

        1.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this research, the dynamics equations for a demolition fire vehicle were formulated. This was done by developing an interface that allows co-simulation using ADAMS and MATHEMATICA. In this study, MATHEMATICA alone was used to calculate the constrained dynamics equations, to demonstrate the impact force and the constraint Jacobian of the end-effector as any desired location through the x, y and z axes. Then we mathematically derived a model for a unilaterally constrained multi-link. Assumptions about the fire demolition vehicle of the constraint coordinate and the impact issues of the model are discussed in the next sections. The estimation procedure for the dynamics equation showed good approximation results in terms of solving a reaching task problem.
        4,000원
        2.
        2013.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 시설재배에서 참외를 수확할 수 있는 로봇의 엔드이펙터를 개발하기 위한 전단계로서, 참외의 엔드이펙트 중에서 소프트 핸드링이 가능한 그립퍼와 참외 줄기를 절단하는 커터를 설계하기 위해 참외의 기하학, 압축, 절단, 마찰 특성 등을 분석하였다. 그 결과 참외의 길이는 평균 108mm, 직경은 중간지점에서 평균 70mm, 중량은 평균 188g, 부피는 평균 333mL, 진원도는 평균 3.8mm로 나타났다. 참외의 중량(W)에 대하여 길이(L)와 직경(D2)을 변수로 하는 식 W = La × D2 b로부터 비선형 회귀분석을 실시한 결과 a는 2.0279, b는 −0.9998의 상 수값을 가지는 상관관계가 있는 것으로 나타났다. 참외 줄기의 지름은 평균 3.8mm이며, 참외 줄기는 중심으로 부터 반경 5mm 범위 내에서 대부분 분포하였다. 참외의 항복치와 압축강도, 경도의 평균값은 각각 36.5N/cm2, 185.7N/cm2, 636.7N/cm2이며, 참외 줄기의 절단력과 절단강도는 각각 2.87 × 10−2N와 5.60N/cm2로 나타났다. 참외의 마찰계수는 고무가 0.609으로 가장 높게 나타났고, 그 다음으로 알루미늄이 0.393, 스테인레스강이 0.177, 테프론이 0.079로 나타났다. 분석된 자료를 토대로 엔드 이펙터 설계시 동작에 따른 위치 오차와 안전율을 감안 하여, 그립퍼의 및 커터의 크기, 선회반경, 설치위치, 구 동모터의 동력, 재료 및 재질의 선정 등에 적용할 수 있을 것으로 판단되었다.
        4,000원
        3.
        2003.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 실험은 오이수확기의 메니퓰레이터에 장착하는 엔드이펙터를 생각한 것이다. 모터는 DC모터로 기어를 이용하여 작동되며, 동력전달에 있어 균형적인 배분을 이루었고, 따라서 부드러운 작동이 가능하였다. 또한 축을 이용한 베벨기어의 동력 전달로 모터에서 나온 회전력을 기어로 확실히 전달하였고, 결과적으로 오이 과병 절단 rpm에 있어서는 정확한 측정이 가능했다. 주요 연구결과를 요약하면 다음과 같다. 1. 모터는 칼날을 회전시키는데 있어 제어가 쉽고, 정확한 동력전달로서의 베벨기어는 비교적 정확한 결과를 제시했다. 2.실험에서의 반복적인 오이 절단작업에 제시된 결과는, 모든 작물에 적용될 수는 없지만, 오이 과병의 절단은 적정 rpm라 각도를 구하여 기계적 최적상황을 찾았다. 수평에서 위로 30˚각도와 198 rpm에서 효율 적인 절단작업이 이루어 졌다. 3. 엔드이펙터의 구조는 간단하면서도 고장 없이 제작되어야 하고 또한 경량이며 수분에 부식되지 않는 재료를 사용하여 설계하였다
        4,000원
        4.
        2020.06 KCI 등재 서비스 종료(열람 제한)
        Fruit and vegetable harvesting robots have been widely studied and developed in recent years to reduce the cost of harvesting tasks such as labor and time. However, harvesting robots have many challenges due to the difficulty and uncertainty of task. In this paper, we characterize the crop environment related to the harvesting robot and analyzes state-of-the-art of the harvesting robot especially, in the viewpoint of robotic end-effector. The end-effector, an one of most important element of the harvesting robot, was classified into gripper and harvesting module, which were reviewed in more detail. Performance measures for the evaluation of harvesting robot such as test, detachment success, harvest success, and cycle time were also introduced. Furthermore, we discuss the current limitations of the harvesting robot and challenges and directions for future research.
        5.
        2010.11 KCI 등재 서비스 종료(열람 제한)
        This study proposes the design method for the robot rotation arm which the end effector that is connected in end of the arm keeps parallel motion even though the robot arm rotates. So far, most robot arm rotates together the end effector when the arm rotates. For this, this study proposes the mechanism that the arm is linked to each 4 parallel link so that rotation is possible by 4 pins, and the rotation arm connects 2 joints of diagonal line direction to a link in each 4 joint for rotation, and designs so that can change length of the link. For verification of design, this study targeted that develop the rotation arm for medical examination that use in ophthalmology. It is important that a medical robot offers comport to patient and design compactly so that medical examination and treatment space may can be defined enough. It is designed so that all drive elements may be positioned on interior of the arm and optimization of design for main parts was carried out in this study for this. The robot arm which is developed in this study manufactured to use by medical phoropter arm, and got good result by an experiment. The robot rotation arm which is proposed in this study is judged to contribute very effectively in case use of a medical robot arm for medical examination and treatment, also the robot arm which the end effector that is connected in the end of the arm needs to keep parallel motion. And, the robot arm which is developed in this study made an application as license.