        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a condensate drain valve was newly installed in the steam inlet pipe line of the soot blower to reduce the amount of condensate contained in the steam for the soot blower. When the economizer is inactive, the condensate drain valve on the soot blower steam inlet pipe line is always opened to drain the condensate. It is intended to reduce environmental pollution and improve economizer performance by reducing the water hammer that inevitably occurs in facilities using steam, and reducing the amount of condensate water generated during the shutdown of the soot blower and the release of soot containing condensate water into the atmosphere when removing soot.