During the initial cooling period of spent nuclear fuel, Cs-137 and Sr-90 constitute a large portion of the total decay heat. Therefore, separating cesium and strontium from spent nuclear fuel can significantly decrease decay heat and facilitate disposition. This study presents analytical technique based on the gas pressurized extraction chromatography (GPEC) system with cation exchange resin for the separation of Sr, Cs, and Ba. GPEC is a micro-scaled column chromatography system that allows for faster separation and reduction volume of elution solvent compared to conventional column chromatography by utilizing pressurized nitrogen gas. Here, we demonstrate the comparative study of the conventional column chromatography and the GPEC method. Cation exchange resin AG 50W-X12 (200~400 mesh size) was used. The sample was prepared at a 0.8 M hydrochloric acid solution and gradient elution was applied. In this case, we used the natural isotopes 88Sr, 133Cs, and 138Ba instead of radioactive isotopes for the preliminary test. Usually, cesium is difficult to measure with ICP-OES, because its wavelengths (455.531 nm and 459.320 nm) are less sensitive. So, we used ICP-MS to determine the identification and the recovery of eluate. In this study, optimized experimental conditions and analytical result including reproducibility of the recovery, total analysis time and volume of eluents will be discussed by comparing GPEC and conventional column chromatography.
This study was performed to evaluate the separation of Sr, Cs, Ba, La, Ce, and Nd using gas pressurized extraction chromatography (GPEC) with anion exchange resin for the quantitation of Neodymium. GPEC is a micro-scaled column chromatography system that provides a constant flow rate by utilizing nitrogen gas. It is overcome the disadvantages of conventional column chromatography by reducing the volume of elution solvent and shortening the analysis time. Here, we compared the conventional column chromatography and the GPEC method. The whole analysis time was decreased by nine times and radioactive wastes were reduced by five times using the GPEC system. Anion exchange resin 1-X4 (200~400 mesh size) was used. The sample was prepared at a 0.8 M nitric acid in methanol solution. The elution solvent was used at a 0.01 M nitric acid in methanol solution. Finally the eluate was analyzed by ICP-MS to determine the identification and recovery. In this case, we applied the natural isotopes of LREEs (139La, 140Ce, and 144Nd) and high activity nuclides (88Sr, 133Cs, and 138Ba) instead of radioactive isotopes for the preliminary test; as a result, unnecessary radioactive waste was not produced. The recoveries were 93.9%, 105.9%, 91.9%, 47.6%, 35.9%, and 79.9% of Sr, Cs, Ba, La, Ce, and Nd, respectively. The reproducibility of recoveries by GPEC were in the range 2.8%–10.9%.
A new method for chemical separation of light rare-earth elements (LREEs) using gas-pressurized extraction chromatography (GPEC) is described. GPEC is a microscale column chromatography system that features a constant flow of solvents (0.1 mL/min), which is created by pressurized nitrogen gas. The separation column with a Teflon tubing was packed with LN resin. We evaluated the separation of Ba, La, Ce, and Nd using various elution solvents. Here, we applied the natural isotopes of LREEs (La-139, Ce-140, and Nd-144) and barium (Ba-138) instead of radioactive isotopes for the preliminary test and reducing unnecessary radioactive waste. The column reproducibility of the proposed GPEC system ranged from 2.4% to 4.9% with RSDs of recoveries, and the column-to-column reproducibility ranged from 3.1% to 6.3% with RSDs of recoveries. This proposed GPEC method provides robust analysis and facilitates production of lesser chemical wastes and faster separation owing to the use of low solvent volume compared to traditional column chromatography.