This study deals with the maximum thermal load analysis and optimal capacity determination method of tank culture system for applying seawater source heat pump to save energy and realize zero energy. The location of the fish farm was divided into four sea areas, and the heat load in summer and winter was analyzed, respectively. In addition, two representative methods, the flow-through aquaculture system and the recirculation aquaculture system were reviewed as water treatment methods for fish farms. In addition, the concept of the exchange rate was introduced to obtain the maximum heat load of the fish farms. Finally, power consumption for heat pumps was analyzed in the view point of sea areas, tank capacity, and exchange rate based on the calculated maximum thermal load.
Most of steam power plant in Korea are heating the feed water system to prevent freezing water flowing in the pipe in winter time. The heating system is operated whenever the ambient temperature around the power plant area below 5 degree Centigrade. But this kind of heat supplying system cause a lot of energy consuming. If we think about the method that the temperature of the each pipe is controled by attaching the temperature measuring sensor like RTD sensor and heat is supplied only when the outer surface temperature of the pipe is under 5 degree Centigrade, then we can save a plenty of energy. In this study, the computer program package for simulation is used to compare the energy consumption load of both systems. Energy saving rate is calculated for the location of Youngweol area using the data of weather station in winter season, especially the January' severe weather data is analyzed for comparison. Various convection heat transfer coefficients for the ambient air and the flowing water inside the pipe was used for the accurate calculation. And also the various initial flowing water temperature was used for the system. Steady state analysis is done previously to approximate the result before the simulation. The result shows that the temperature control system using RTD sensor represents the high energy saving effect which is more than 90% of energy saving rate. Even in the severe January weather condition, the energy saving rate is almost 60%.
후쿠시마 사고 이후 사용후핵연료 저장시설 안전성 재검증 필요성이 증대되고 있는 가운데, 재검증 결 과의 신뢰성 향상을 위해 열부하 평가결과의 정확도 향상이 요구되고 있다. 이를 위한 기초연구로 본 연 구에서는 상대적으로 중요성이 저평가되었던, 저장시나리오, 연소조건 관련 인자와 같이 붕괴열 및 열부 하 평가 영향인자를 도출하고, 고리 4호기를 대상으로 ORIGEN2 코드를 이용해 그 효과를 평가하였다. 대표 저장시나리오에 대한 열부하 평가 결과, 최후 방출 핵연료의 붕괴열은 시나리오에 따라 전체 열부하의 최대 80.42%를 차지해 저장시설 열부하에 지배적인 영향을 미침이 확인되었다. 또한 연소조건 인자로 선택된 축 방향 연소 효과, 연소이력, 비출력 효과에 대한 민감도 분석 수행 결과, 냉각기간이 짧을수록 각 인자의 붕괴열에 대한 영향이 커지는 것으로 확인되었다. 각 인자별로는 비출력, 연소이력, 축 방향 연 소 효과의 순으로 붕괴열에 대한 영향력이 컸으며, 특히 비출력의 경우 방출 직후 평균값의 0.34에서 1.66배, 방출 1년 후에는 평균 대비 0.55에서 1.37배까지 붕괴열 변화를 초래함이 확인되었다. 즉, 저장시 설의 열부하 평가와 같이 냉각기간이 짧은 핵연료에 대한 해석 시 비출력, 연소이력과 같은 연소조건인자 가 해석결과에 매우 큰 차이를 초래할 수 있으므로, 해석결과의 정확도 향상을 위해 기존 해석자의 공학 적 판단에 의거한 임의 인자 대표성 핵연료 선택방식 대신 실제 운전 데이터의 적용 등이 필요할 것으로 보인다. 본 연구 결과는 향후 열부하 해석 결과의 정확도 향상 및 불확실도 평가를 위한 기초자료로 활용 될 수 있을 것으로 사료된다.