This study investigates the stress-strain relations of internally confined hollow concrete filled tube pier reinforced with GFRP tube by uniaxial compression test. The confined concrete subjected multi-axial stresses have been known as the strength of concrete increases significantly. Many researchers have studied in confining effects of CFT which have only outer GFRP tube. In this study, specimens reinforced with outer and inner GFRP tube were tested by uniaxial compression test. To investigate the influence of concrete strength increase by confining conditions in GFRP tube, 13 specimens with different thickness of tube, hollowness ratio and nominal concrete strength were tested and compared with Steel tube.
Recently, there is to increase interest in seismic performance of piers. Hollow section is applied to increasing the seismic performance of piers. However, hollow RC pier becomes the biaixial confining state because hollow part is not confined. The pier is developed brittle failure from inner face in hollow part. A tube is inserted in hollow part to become the weakness. This is ICH RC(Internally Confined Hollow RC) pier. This pier is enhanced stiffness, strength, and ductility by core concrete has triaxial confining stress. In this paper is researched about parameters effect the seismic performance. Parameters are hollow ratio, transverse reinforcement, longitudinal reinforcement, and concrete strength.
Recently study of confining effect in column member is progressed. But these studies are limited to about RC column and external confining effect in hollow column. Internal confining effect in hollow column has not researched that generally assumed the same external confining effect. In this study there are to investigate the internal direction confining effect ICH RC columns. We performed parametric studies to find main parameters that affect the internal confining effect. Parametric study has performed using FEA program (ABAQUS) which parameters are hollow ratio, diameter of column.
교량 건설에 있어서 사용 재료의 품질 개발과 새로운 구조 형식을 개발하는 기술이 지속적으로 발달되어져 왔으며, 현재는 성능 향상 및 재료비 절감 등을 이유로 다양한 중공식 교각이 개발되고 있다. 이러한 중공식 교각은 단면 형상에 따라 사각단면, 원형단면 등으로 나눌 수 있으며, 제작 기술에 따라 중공 RC 교각, 중공 CFT 교각 등으로 세분화할 수 있다. 현재까지는 중공 사각형 RC 교각이 고교각 건설에 주로 이용되고 있는 실정이다.
중공 교각을 사용하는 주된 이유는 사용 재료의 절감을 통한 경제성 확보 및 같은 양의 재료로 유리한 단면상수를 가진 교각 단면을 만들 수 있으며, 교각의 중공부에 의한 교각의 자중을 감소로 인하여, 교각의 질량이 줄어듦으로써, 지진 하중에 대한 응답을 줄일 수 있기 때문이다.
이에 본 연구에서는 중공식 기둥의 한 종류로 선행 연구자들에 의해 개발된 내부 구속 중공 CFT 기둥을 교량의 하부 구조로 적용하여, 응답스펙트럼해석을 이용한 교각의 내진 성능을 평가를 수행하였다.
본 연구에서의 매개변수는 내부 구속 중공 CFT교각의 중공비이다. 기존 중실교각대비 질량저감 효과를 고려하기 위하여, 중공비는 0.7, 0.8, 0.9를 각각 선정하여, 중공비에 따른 단면을 설계하였다. 축강도 기준, 모멘트 성능 기준, 경제성 기준, 동일단면의 설계를 통하여, 교각의 중공비에 따른 내진 응답을 산출하였으며, 중실기둥대비 성능향상 효과를 도출하였다.