검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 7

        1.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study proposes a technique to dissipate the energy of a rocking wall installed on a frame by using a metallic damper. The rocking behavior is to turn left and right about the wall vertical axis. The development system is a method of dissipating energy by installing a damper which is the like on a large displacement portion. Experimental results showed that in case of shorter strut make strength capacity increasement and in case of longer strut make deformation capacity increasement. The higher the strut height, the better the energy dissipation capacity. The proposed equation for estimating the steel damper strength applied to this study is a straight type strut damper. However, it is not suitable for calculation of the strength of clamped type strut damper where both flexural behavior and shear behavior are mixed.
        4,000원
        2.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 에너지 흡수형 강재 댐퍼를 이용하여 손상순서를 제어함으로써 주구조체를 재사용 할 수 있는 철골조시스템을 개발하고, 지진응답특성을 파악하는 것이다. 이를 위하여 강재 댐퍼의 형상을 제안하고, 제안된 강재 댐퍼의 변형 형상과 응력 분포를 알아보기 위하여 범용 유한요소해석 프로그램인 ANSYS(ver.10.0)을 이용한 비선형 유한요소해석을 수행하였다. 또한 지진응답특성을 파악하기 위하여 실대형 사이즈 5.4m×2.4m의 1층 철골조 실험체 4개를 설계 및 제작하여 유사동적 지진응답실험을 수행하였다. 본 연구에서 제안하는 강재 댐퍼를 제진요소로 사용하는 경우, 주구조체에 비하여 높은 강성을 갖는 댐퍼가 소폭의 변위에 먼저 소성화함으로써 이력에 의한 지진에너지를 흡수할 수 있으며, 지진응답에서 유리한 것이 판명되었다.
        4,000원
        3.
        2015.11 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 내진설계 이전에 지어진 학교 건물을 대상으로 내진보강효과를 알아보기 위하여 벽체로 지지되는 강재이력형 감쇠 장치를 설치하여 기존 비내진 설계된 보강 RC골조 실험결과와 비교 분석하였다. 실험결과, 비내진 설계된 실험체는 좌․우측 기둥의 상․하부에 피해가 집중되면서 급격한 강도저하와 함께 취성적인 전단파괴의 양상을 나타낸 반면, 더블 I형 감쇠장치를 보강한 실험체는 감쇠장치 보강으 로 강도 및 강성의 증가와 함께 탄소성 거동을 보이면서 에너지 흡수 능력이 큰 타원형의 이력특성을 나타내었다. 또한, 두 실험체의 강성저하 를 비교한 결과 더블 I형 감쇠장치를 보강한 실험체가 강성저하를 방지하는데도 효과적임을 알 수 있었다. 에너지소산능력도 더블 I형 감쇠장 치를 보강한 실험체가 비보강 실험체에 비해 약 3.5배의 향상된 결과를 나타내었다. 이러한 에너지소산능력의 증진은 내력과 변형 능력의 증진 에 따른 결과라고 사료된다.
        4.
        2014.10 서비스 종료(열람 제한)
        To develop the external strengthening method which are considered metallic damper in rocking wall system, basic behavior test is conducted on straight strut type metallic damper. Based on test results, it was found that the motion of developed rocking wall system can change properly from rotate behavior to shear behavior.
        5.
        2013.10 서비스 종료(열람 제한)
        To evaluate the displacement dependency of metallic damper which has straight type steel strut, cyclic tests are conducted with the target displacement variables on constant velocity. Form this, width to height ratio of strut is 0.079. From the strength and energy dissipation capacity comparison, cyclic test results are short of the static test results. Therefore more detailed design which are considering target structure period and dynamic characteristics is needed.
        6.
        2012.11 서비스 종료(열람 제한)
        To evaluate the strength and energy dissipation capacity of straight type metallic damper, cyclic tests are conducted with the target displacement variables on constant velocity. From the strength and energy dissipation capacity comparison, cyclic test results are short of the static test result. Therefore more detailed cyclic tests and researches are needed.
        7.
        2010.05 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 기존 건축물의 내진성능을 향상시키기 위해 시공성과 설치 비용적인 측면에서 상대적으로 우수한 강재댐퍼를 대상으로 기존 개발된 장치와 새로 개발된 형상의 장치에 대한 평가를 해석적으로 수행하였다. 해석결과는 강도 및 에너지 소산능력으로 평가하였으며, 제안된 내력 산정식의 적용을 아울러 평가하였다. 연구대상 댐퍼의 스트럿 형상은 V형, S형이며, 댐퍼의 스트럿 높이와 각도를 주요 변수로 한 후 ABAQUS를 이용하여 유한요소 해석하였다. 해석은 최대변위를 50mm로 하고 점진적인 이력변위곡선을 적용하여 수행하였다. 항복강도, 최대강도, 에너지 소산능력 평가결과, V형 및 S형 모두 우수한 성능을 보유한 것으로 평가되었으며, 또한 스트럿 각도 60° 및 높이 140, 200 mm의 성능이 안정적인 것으로 평가되었다. 전체적으로는 S형의 응답이 V형보다 안정적인 것으로 평가되어, S형 강재댐퍼의 적용성이 V형보다 유리한 것으로 평가되었다.