검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 3

        1.
        2023.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we analyzed the changes in concentrations of volatile fatty acids (VFA), phenols, and indoles, as well as odor contribution in pig slurry. The pig slurry was stored for approximately two months after the manure excretion of pigs which had been fed 3% level of peat moss additive. The investigation was carried out through lab-scale experiments simulating slurry pit conditions within pig house. Throughout the storage period, the concentration of VFA exhibited a tendency to be 11%-32% higher in the pig manure treated with peat moss as compared to the control group. From a concentration perspective, phenol and acetic acid accounted for the majority of the total odor compounds produced during the pig slurry storage period. However, their significance diminished when the concentration of odoros compounds are converted into odor activity value and odor contribution. Despite the odor reduction effect of the ammonia (NH3) adsorption by peat moss, if it cannot effectively reduce the high odor-contributing compounds such as indoles and p-cresol, the sole use of peat moss may not be considered an effective means of mitigating odors produced by pig slurry. According to this study, indoles, p-cresol, skatole, and valeric acid were consistently revealed as major odor-contributing substances during the two-month storage of pig slurry. Therefore, a comprehensive odor mitigation methodology should be proposed, taking into consideration the odor generation characteristics (including temporal concentration and odor contribution) of pig slurry-derived odors during storage.
        4,200원
        2.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, public complaints about unpleasant odor are increasing, particularly in urban areas. One of the odor sources is meat grilling restaurants in the vicinity of the residential areas. In this study, we characterized the odorous compounds generated from the stack of grilling restaurants, and evaluated the removal efficiency of the control facilities. As a result of the field investigation, the dilution index of the complex odor exceeded 500 times that of all test restaurants. The main substance was acetaldehyde. In addition, the correlation coefficient (R2) between the total odor and the sum of odor activity values (SOAV) was 0.73, a value high enough to indicate significant responsibility. The performance of the control facility has been shown to be strongly influenced by maintenance activities, such as cleaning and filter replacements.
        4,000원
        3.
        2016.09 KCI 등재 서비스 종료(열람 제한)
        The purpose of this study was to obtain the basic data needed to identify the impact of the odor, emitted from the Ochang Scientific Industrial Complex area on the surrounding residential areas by measuring and confirming odor compounds. The analysis showed that complex odors were diluted from around 4 to 1. The offensive odor measurement results showed that among the sites, site 1 was highest in sulfur compounds, site 2 was highest in toluene, site 3 was highest in trimethylamine, and site 4 was highest in buthylaldehyde. It cannot be decided to be odor-causing compounds for higher odor concentration because each odor substance has a different odor threshold value. According to the odor contribution analysis for each site, site 1, site 2, and site 4 contained high buthylaldehyde concentrations, and site 3 had a high level of trimethylamine. It could be determined that highly evaluated substances were main causes to result in substance for each site.