In regions of low-to-moderate seismicity, various types of lap splices are used for longitudinal reinforcement of columns at the plastic hinge zones. The seismic performance of such lap spliced columns, such as strength, deformation capacity, and energy dissipation, is affected by material strengths, longitudinal re-bar size, confinement of hoops, lap splice location, and lap splice length. In the present study, cyclic loading tests were performed for columns using three types of lap splices (bottom offset bar splice, top offset bar splice, and splice without offset bend). Lap splice length(40db and 50db) was also considered as test parameters. Ties with 90-degree end hooks were provided in the lap splice length. The test results showed that strength, deformation capacity, and energy dissipation of columns significantly differed depending on the details and the length of lap splices. The bottom offset bar splice showed high ductility and energy dissipation but low strength; on the other hand, the top offset bar splice and the splice without offset bend showed high strength but moderate ductility and energy dissipation.
Various non-seismic tie details are frequently used for one- and two-story small buildings because the seismic demand on their deformation capacities is not relatively significant. To evaluate the effects of the non-seismic tie details on the seismic performance of reinforced concrete columns, six square columns with a cross section of 400 × 400 mm and six rectangular columns with a cross section of 250 × 640 mm were tested. The anchorage details at both ends and spacing of tie hoops, along with the cross-sectional shape and the magnitude of axial load, were considered as the primary test parameters. Test results showed that square columns had higher stiffness and lower lateral deformation rather than rectangular columns. Both lap spliced tie and U-shaped tie provided comparable or improved seismic performance to 90° hook tie in terms of maximum strength, ductility, and energy dissipation. The predicted curves with modeling parameters in ASCE41-13 were conservative for test results of lap spliced tie and U-shaped tie specimens since plastic behavior after flexural yielding could not be considered. For economical design, ASCE41-13 should be revised with various test results of tie details.
The purpose of this study is to investigate the seismic performance of hollow RC bridge columns with reinforcement details for material quantity reduction. The proposed reinforcement details provide economy, are rational and shorthen the construction periods. The accuracy and objectivity of the assessment process can be enhanced by using a sophisticated nonlinear finite element analysis program. Solution of the equations of motion is obtained by numerical integration using Hilber-Hughes-Taylor (HHT) algorithm. The adopted numerical method gives a realistic prediction of seismic performance throughout the input ground motions for several test specimens investigated. As a result, the proposed reinforcement details for material quantity reduction develop equal performance to that required for existing reinforcement details.
In this study, the shake table test of the damaged reinforced concrete frame was carried out and the damage and dynamic response characteristics were evaluated. The static lateral-cyclic test for the specimen was followed by the dynamic test. As a result of the shake table test, damage was concentrated on existing cracks and the maximum inter-story drift ratio was calculated as 1.94% at the final excitation step.
5층 이하 비내진상세를 가지는 철근콘크리트 건축물의 지진시 긴급 위험도 평가를 위한 부재의 정량적 손상도 평가 기준을 제시하기 위하여 실대형 크기의 철근콘크리트 1층 1경간 골조 실험체의 정적실험을 실시하였다. 실험결과, 실험체는 기둥의 휨항복후 전단파괴에 의하여 파괴되었으며, 기둥과 접합부에 균열, 압괴 등의 손상이 발생한 반면, 보에는 균열 등의 손상이 거의 발생하지 않았다. 이와 같이 비내진 상세를 가지며 휨항복후 전단파괴하는 철근콘크리트 기둥의 손상도를 5단계로 분류하고 손상단계별 한계상태를 평가하기 위한 정량적 기준으로서 지진시 상대적으로 측정이 용이한 잔류 층간변형각과 잔류 균열폭을 이용하였다. 손상한계상태의 잔류 층간변형각 및 잔류 균열폭은 실험결과에 따른 손상한계상태의 최대 층간변형각과의 관계에 의하여 결정하였으며, 한계 최대 층간변형각은 실험결과에 의한 부재의 하중-변형 관계 및 손상발생 현황을 바탕으로 결정하였다. 한계 잔류 층간변형각은 해당 최대 층간변형각에 의한 잔류 층간변형각 중의 최대값 이상이 되도록 하였으며, 한계 잔류 균열폭은 해당 최대 층간변형각에 의한 잔류 전단균열폭의 최소값 및 잔류 휨균열폭의 평균값으로 결정하였다. 한편, 본 논문을 통하여 제시한 손상한계상태의 잔류 층간변형각과 잔류 균열폭은 지진으로 동일한 부재 변형이 발생할 경우 내진설계가 실시된 부재를 대상으로 하는 국외 손상도 평가 기준에 의한 값보다 작은 것으로 나타났다.