This study presents a rapid and sequential radiochemical separation method for Pu and Am isotopes in radioactive waste samples from the nuclear power plant with anion exchange resin and TRU resin. After radionuclides were leached from the radioactive waste samples with concentrated HCl and HNO3, the sample was allowed to evaporate to dryness after filtering the leaching solution with 0.45 micron filter. The Pu isotopes were separated in HNO3 medium with anion exchange resin. For leaching solution passed through anion exchange column, the Am isotopes were separated with TRU resin. The purified Pu and Am isotopes were measured by alpha spectrometer, respectively, after micro-precipitation of neodymium. The sequential radiochemical separation of Pu and Am isotopes in radioactive waste samples using anion exchange resin and TRU resin was validated with ICP-MS system.
This study presents a rapid and quantitative radiochemical separation method for Nb isotopes in radioactive waste samples from the nuclear power plant with anion exchange resin after Fe coprecipitation. After radionuclides were leached from the radioactive waste samples with concentrated HCl and HNO3, the Nb isotopes were coprecipitated with Fe after filtering the leaching solution with 0.45 micron HA filter, while the Sr, Tc and Ni isotopes were in the solution. The Nb isotopes were separated in HCl medium with anion exchange resin. The purified Nb isotopes were measured using a low level liquid scintillation counter after installing quenching curve with standard Nb-94 isotopes. The separation method for Nb isotopes investigated in this study was applied to neutron dosimeter samples from the nuclear power plant after validating the Nb activity concentration with gamma spectrometry system.