검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 3

        1.
        2022.05 구독 인증기관·개인회원 무료
        The radwaste facility management team is preparing for clearance of 4 MCAs in The Radwaste Form Test Facility (RFTF). The targeted waste was used for clearance level radioactive waste sample analysis and has been used for this purpose since the early 2000s. Due to the characteristics of clearance level radioactive waste, the concentration of radioactivity is very low and MCA is used with Marinelli beakers the possibility of contamination is low. Moreover, the radiation detector should not be contaminated with radioactive materials, it should be less than the clearance level. These detectors were considered surface contamination materials. To detect the contaminated spot of each material, we scanned the whole surface of a material with a gamma survey meter. After that, we took a sample from 1×1 m2 and a total of 30 samples from each MCA. The wiped filter paper was analyzed with alpha, beta low background counting systems. The results of the analysis of the smear sample of total alpha and beta nuclide radioactivity were less than MDA (α: 2.88×10−5 Bq·cm−2, β: 3.07×10−5 Bq·cm−2). The major nuclide in this facility is Co-60 and Cs-137 therefore we analyzed gamma nuclide activity with HPGe. The maximum specific activity was Co-60: 2.31×10−5 Bq·cm−2, Cs-137: 1.96×10−6 Bq·cm−2. If it is satisfied with the clearance criteria, detectors will be reused at the Radioactive Waste Treatment Facility (RWTF) room # 7251 uncontrolled area.