Sewerage age more rapidly than other facilities, leading to the destruction of the pipeline. Therefore, the replacement of old sewer pipes through long-term construction is costly. In order to solve this problem, this study investigated the ferronickel based sewer pipe with improved chemichal resistance and durability from concrete rigidity pipe. ABAQUS was used as the finite element analysis program and the load was calculated by the method given in the sewage facility standard. Therefore, the results of this study can be referenced in the design and construction of sewer pipes.
For the CLMS using FA as powder and S and SS as fine aggregates, respectively, in order to improve flowability by preventing material separation and securing quantity of minimum unit and to secure maximum strength by repressing bleeding, the most reasonable and optimal combinations of FA+S and FA+SS were f/a 20 and f/a 60, respectively.
본 연구에서는 각종 산업부산물 및 도시형 리싸이클링 재료 등의 재생자원을 안전하게 유효 이용할 수 있는 방안으로 BFS 및 SS를 활용한 저강도 콘크리트의 기초적 물성을 파악하기 위하여 플로우 및 블리딩, 일축압축강도, 환경오염평가를 중심으로 실험을 실시하였다. BFS 및 SS를 활용한 저강도 콘크리트의 경우 최소단위수량의 확보를 통한 유동성 개선 및 블리딩율 억제 또한, 현장 적용성을 고려한 일축압축강도의 확보에 있어 사용 잔골재의 차이에 상관없이 BFS 6000 이상을 30% 범위에서 혼입하는 것이 가장 유효한 것으로 나타났다. 특히, SS의 유효 활용 측면에서 BFS 8000을 30% 범위에서 혼합하여 사용하면 유동성 개선 및 블리딩율 억제, 일축압축강도의 확보는 물론 현장 적용에 있어 가장 최적의 배합조건으로 나타났다. 한편, SS를 활용한 시멘트 개량토를 대상으로 유해물질 함유량 및 용출시험을 실시한 결과 모두 환경 기준치 이하를 만족하는 것으로 나타나 주변 환경에 미치는 영향은 없는 것으로 확인되었다.
콘크리트 하수 암거는 항상 유해이온에 노출되어 있으므로 사용기간의 증가에 따라 내구적인 문제점을 보이며, 이러한 열화는 구조적인 문제로 진전된다. 콘크리트 하수암거는 일단 매립 후 유지관리가 어려우므로 초기에 높은 내구성 및 안전성을 요구한다. 최근 들어 역학적 특성과 내구적 성능의 개선을 위하여 폴리머 콘크리트가 사용되고 있다. 본 논문에서는 폴리머 콘크리트를 이용한 하수암거에 대한 공학적 성능을 평가하였으며, 축소 모형을 통하여 이음부의 누수와 접착강도를 평가하였다. 제작된 폴리머 하수암거는 100MPa 이상의 높은 압축강도를 확보하였으며, 낮은 투수성 및 염소이온 침투성을 확보하고 있었다. 또한 내화학성 및 생물학적 시험 등에서도 우수한 저항성을 확보하고 있었다. 축소모형실험을 통하여, 이음부 누수가 없고 높은 접착강도를 확보하고 있음을 평가하였으며 연결부의 일체거동을 확인하였다. 본 연구에서 제작된 프리캐스트 폴리머 하수암거는 하수도관과 같이 열악한 환경조건에 적극적으로 사용될 수 있다고 판단된다.