검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2

        1.
        2016.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The reduction in solar radiation transmittance(SRT) because of dust and other foreign materials was experimentally tested in two types of greenhouses with the intent to obtain basic data for establishing maintenance and management guidelines for greenhouse cover materials. The test results in the greenhouse in Gyehwa-do estimated the amount of removed dust at 16.8– 1,021.6 mg·m-2(average: 520.7 mg·m-2), and the dust amount varied widely with the measurement points. The SRT measured in triplicate before and after dust removal ranged 68.5–80.9% and 80.9–87.2%, respectively; thus, there was an improvement in SRT by about 8.1% after dusting. In contrast, the greenhouse in Gyeongsang National University did not exhibit great fluctuations in the coefficient of determination(correlation coefficient) regardless of the daily total, average, or maximum horizontal surface radiation; the SRT gradually decreased over time. The SRT increased or decreased, showing clearly different patterns in summer and winter half years, as did the coefficients of determination(0.468–0.828). Dust was measured to be in the range 747.1– 983.1 mg·m-2(average: 840.1 mg·m-2), without great differences between the measurement points, unlike in the case of the greenhouse in Gyehwa-do. The SRT measured before and after the dust removal ranged 73.0–80.5% and 81.0–88.6%, respectively, showing an average improvement of about 7.9%. The SRT measured after washing with water ranged 88.7–90.6%, demonstrating a greater improvement with an average increase rate of 13.0%, which is 5.1% higher than the increase rate after dust removal. These results suggest that although washing with water rather than dust removal improves SRT to a greater extent(13.0% vs. 7.9%), dust removal alone is considered to provide considerable improvement in SRT. Comparison of the images of the unused film and pre-dusting film under the microscope revealed that foreign materials such as dust were adhered to the pre-dusting film, and variations were observed according to the magnification ratio and photographed area.
        4,200원
        2.
        2002.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        온실의 경우 구조재가 광투과율에 많은 영향을 주기 때문에 기상조건에 따라 달라지는 산란광과 직달광의 비율에 따라 투과율이 달라질 수 있다 따라서 기상조건에 따른 온실내부의 광투과율을 구명할 필요가있다. 전천일사량은 기상청에서 제공하는 기상자료에서 쉽게 얻을 수가 있는 반면에 광합성유효광량자속의 자료는 직접 측정하지 않고는 구하기가 어렵다. 그러나 전천일사량과 광합성유효광량자속의 상관관계가 얻어지면 전천일사량으로부터 광합성유효광량자속을 쉽게 구할 수가 있을 것이다. 따라서 우리나라 온실에 대하여 기상조건에 따라 광합성유효광양자속을 산정할 수 있는 상관식의 개발이 필요하다. 본 연구는 실험을 통하여 온실의 수관부에서의 기상조건에 따른 광합성유효광량자속의 투과율을 산정하고 전천일사와 광합성 유효광량자속과의 상관관계를 구명하기 위하여 수행되었다. 산란광이 많은 흐린 날과 직달광이 많은 맑은날의 투과율 변화는 상당한 차이가 있음을 확인할 수 있었으며, 온실의 투과율은 기상조건에 따라 다르게 적용되어야 할 것으로 판단되었다. 온실의 전천일사량 투과율을 광합성유효광량자속의 투과량을 산정하는데 그대로 이용할 수 있을 것으로 분석되었다. 비록 맑은 날에 비하여 흐린 날의 상관도는 낮지만 상관식의 기울기는 큰 것으로 나타나 운량의 증가와 더불어 전천일사량 중에서 광합성유효광량자속의 비율이 증가하는 것을 확인 할 수 있었다. 시간당 광합성유효광량자속과 전천일사량의 상관식을 유도하였으며, 이러한 상관식을 이용한다면 시간당 전천일사량을 이용하여 시간당 광합성유효광량자속을 추정하는데 적절히 이용할 수 있을 것으로 판단된다.
        4,000원