검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2

        1.
        2014.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, we analyzed the characteristics of the mass flow rate and velocity of the refrigerant in response to a change in the number of holes and the diameter size(Type-1~4) of the valve guide refrigerant to flow from Pc to Ps when the pressure is constant. Type-1 is 40% higher mass flow flowing in the direction of Ps as compared with the Pc mass flow rate. Type-2 is 64% higher mass flow flowing in the direction of Ps as compared with the Pc mass flow rate. Type-3 is 50% higher mass flow flowing in the direction of Ps as compared with the Pc mass flow rate. Type-4 is 47% higher mass flow flowing in the direction of Ps as compared with the Pc mass flow rate.
        4,000원
        2.
        2013.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, the current of ECV block is connected to compressor crankcase on which the Pc port of Ps port Euro is formed(Type-1). Pc Port Internal Bellows are supposed to be affected by changes at the flow of refrigerant to the solenoid valve inside inhalation. There is Ps port at the direction of flow characteristic in predicting and analyzing. At suction pressures of 0.2MPa and 1.5MPa, maximum flow rates become 46m/s and 129m/s respectively. The refrigerant is discharged by compressor rotation around the axis of rotation from the inflow of port(Pd)(Type-2). By predicting and analyzing inlet flow, suction pressures become 2.7MPa and 3.6 MPa when maximum flow rates of 177.5m/s and 205m/s are affected on Pc ports of Euros with pressures of 1.2KPa and 3.8KPa respectively. This study result can be applied as the basic data for design of ECV.
        4,000원