The author has proposed and verified the accuracy through experiments on a method of measurement through the use of sound waves that not only can quantitatively measure each of the dual directions of the fiber axis with high accuracy of membrane tension created on the surface of the membrane structure, but also can be easily operated in the field of construction. This paper reports the solution for problems of variables caused in the process of downsizing of the measurement equipment in order for practical use, and verifies the correspondence possibility of various stress ratios.
This paper describes a prototype mechanical white noise generator has a source level of more than 170.0 dB (re 1µPa at 1 m) at the frequency range of 10 Hz to 100 kHz. The results of performance evaluation of the generator are as follows. The average source level of the generator measured by a step of 15°in horizontal (0 to 360。, 25 points) was 185.2 (SD (standard deviation): 2.3) dB (re 1µPa at 1 m). The maximum and minimum source levels were appeared at the frequency range of 2.5 to 5.0 kHz and around 100 kHz, respectively. The average source levels at 0°, 90。, 180。and 270° were 162.9 (SD: 10.6), 168.4 (SD: 10.0), 162.1 (SD: 9.1) and 166.5 (SD: 11.1) dB (re 1µPa at 1 m). The average source level measured by a step of 30° in vertical was 184.9 (SD: 2.2) dB (re 1µPa at 1 m). The relative maximum variation width of the source levels in horizontal and in vertical measurement were less than 7.0 dB and 1.0 dB, respectively.
This study examines the effects of different environments on the application of hemiplegia patients circuit balance training. Group 1 performed circuit balance training without any auditory intervention Group 2 performed training in noiseless environments and Group 3 performed training in white noise environments. First, among lower extremity muscular strength evaluation items, maximum activity time(MAT) was not significantly different(p>.05). Maximum muscle strength(MMS) increased significantly in Group 3(p<.01), there was no significant difference in MMS among the groups. Average muscle strength(AMS) indexes also significantly increased in Group 3(p<.01), there was no significant difference in AMS among the groups. Second, among balancing ability evaluation items, Berg's balance scale(BBS) scores significantly increased in all groups(p<.05), BBS scores were significantly difference among the groups. Based on the results, Group 1, 2 and Group 1, 3 showed significant increases (p<.05). Functional reach test(FRT) values significantly increased in Group 2, 3(p<.05), and there was no significant difference in FRT values among the groups. Timed up and go(TUG) test values significantly decreased in Group 2, 3(p<.05), and there was no significant difference in TUG test values among the groups. Third, among walking speed evaluation items, the time required to walk 10m significantly decreased in all groups(p<.05), and there was no significant difference in the values among the groups. Average walking speeds showed significant increases in Group 1, 3(p<.05), and there was no significant difference in the values among the groups. Based on the results of this study, noise environments should be improved by either considering auditory interventions and noiseless environments, or by ensuring that white noise environments facilitate the enhancement of balancing ability.
휨이나 압축에 저항할 수 없는 막재료에 적절한 장력을 도입함으로써 안정화 되는 막구조물은, 유지 관리면에 있어서 막면에 도입되어 있는 장력을 설계대로 유지하는 것이 매우 중요하지만, 준공후 막면에 도입되어 있는 장력을 정확하게 파악하기가 어렵다. 저자들은, 직방형의 경계를 가지는 막을 가청역의 음파를 이용해 진동시키고, 진동하는 막의 공진진동수를 측정함으로써 간접적으로 막장력을 측정하는 방법을 제안하고, 막을 진동시키는 음파로서 정현파와 화이트 노이즈를 이용해 검증실험을 해 왔다. 본 논문은 주요 막재료를 이용해 행한 막장력 측정 이론의 검증을 위한 실험 결과와, 실재하는 막구조물의 장력측정을 통해, 본 측정장치의 정확성과 폭 넓은 적용성 및 측정에 있어서의 안정성을 검증한다.
본 연구에서는 진동대 실험을 통해 얻은 동적 데이터를 이용하여 TDL의 동적 비선형 특성에 대한 연구를 수행하였다. 현재까지 TDL의 설계는 액체의 비선형 거동이 나타남에도 불구하고 TMD 근사이론이나 선형파동이론과 같은 선형 거동을 가정으로 설계되어 지는 한계를 가지고 있다. 또한 조화하중과 같은 특정진동수에 지배되는 하중형태에 대한 TDL의 동적 비선형 특성이 규명되었지만 백색잡음과 같은 특정진동수 성분에 지배되지 않은 하중형태에 대한 TDL의 동적 비선형 특성은 아직까지 검증된 바가 없다. 본 논문은 백색잡음을 이용하여 가진 하중 크기에 따른 TDL의 동적 비선형 특성을 검토하여 설계 시 필요한 동조액체감쇠기의 감쇠비, 고유진동수비 및 유효질량비를 평가할 수 있는 산정식을 제안하였다.
디지털미디어의 사운드는 인간의 감각을 자극하여 커뮤니케이션을 수행한다. 소리 자극은 생리적 흥분을 가져오고 반응에 민감한 상태로 각성시키는데, 이는 심장박동, 혈압, 뇌파신호로 나타난다. 본 논문에서는 이완효과가 있는 백색잡음을 혼합한 게임음악과 백색잡음이 섞이지 않은 게임음악을 듣는 게임 플레이어의 뇌파변화를 검사했다. 실험은 두 그룹으로 나누어 진행되었으며 A 그룹은 백색잡음이 섞인 게임음악을, B 그룹은 백색잡음이 섞이지 않은 게임음악을 들으며 게임을 플레이했다. 두 그룹의 전전두엽 뇌파 변화를 측정한 결과 좌뇌에서는 백색 잡음의 이완효과가 나타났으며, 우뇌의 경우는 기대치에 미치지 못했다. 본 연구는 백색잡음의 이완효과를 이용한 기능성 심리치료 게임을 개발하기 위한 기본 연구가 될 것이다.