PURPOSES : A geo-grid pavement, e.g., a stress-absorbing membrane interlayer (SAMI), can be applied to an asphalt-overlay method on the existing surface-pavement layer for pavement maintenance related to reflection cracking. Reflection cracking can occur when a crack in the existing surface layer influences the overlay pavement. It can reduce the pavement life cycle and adversely affect traffic safety. Moreover, a failed overlay can reduce the economic value. In this regard, the objective of this study is to evaluate the bonding properties between the rigid pavement and a SAMI by using the direct shear test and the pull-off test. The predicted fractural energy functions with the shear stress were determined from a numerical analysis of the moving average method and the polynomial regression method.
METHODS : In this research, the shear and pull-off tests were performed to evaluate the properties of mixtures constructed using no interlayer, a tack-coat, and SAMI with fabric and without fabric. The lower mixture parts (describing the existing pavement) were mixed using the 25-40-8 joint cement-concrete standard. The overlay layer was constructed especially using polymer-modified stone mastic asphalt (SMA) pavement. It was composed of an SMA aggregate gradation and applied as the modified agent. The sixth polynomial regression equation and the general moving average method were utilized to estimate the interlayer shear strength. These numerical analysis methods were also used to determine the predictive models for estimating the fracture energy.
RESULTS: From the direct shear test and the pull-off test results, the mixture bonded using the tack-coat (applied as the interlayer between the overlay layer and the jointed cement concrete) had the strongest shear resistance and bonding strength. In contrast, the SAMI pavement without fiber has a strong need for fractural energy at failure.
CONCLUSIONS : The effects of site-reflection cracking can be determined using the same tests on cored specimens. Further, an empiricalmechanical pavement-design analysis using the finite-element method (FEM) must be done to understand the appropriate SAMI application. In this regard, the FEM application analysis and bonding property tests using cored specimens from public roads will be conducted in further research.
활성금속브레이징법으로 계면접합된 AlN/Cu 접합체의 잔류응력 완화에 미치는 Mo 중간재의 영향을 조사하였다. 유한요소법에 의한 응력 해석과 접합체 강도 측정, 파단면의 관찰을 행하였으며, 이들 결과를 비교, 분석하였다. 응력 해석 결과로부터, Mo 중간재를 사용할 경우 최대 잔류 주응력이 형성되는 위치가 AlN/삽입금속 계면으로부터 삽임금속/Mo 계면을 통하여 Mo 내부로 이동됨을 확인하였다.접합체의 자유표면에 형성되는 인장성분의 응력집중 위치는 Mo 중간재 두께가 증가됨에 따라 Cu/Mo 계면과 Mo/AlN 계면의 두 곳으로 분리되었으며, AlN측 잔류응력의 크기는 크게 감소하였다. 중간재를 사용하지 않은 경우 최대 접합강도가 52 MPa로 낮은 강도를 보였으나, 두께 400μm 이상의 Mo 중간재를 사용한 접합체의 경우, 200 MPa 이상, 최대 275 MPa의 접합강도를 얻을 수 있었다.
Ag-Cu-Ti 삽입금속을 이용하여 제조된 AlN/Cu와 AlN/W 활성금속브레이징 접합체의 잔류응력을 유한요소법으로 탄성 및 탄소성 해석을 행하여 그 결과를 접합강도 측정 결과와 파단 거동 관찰 결과와 비교, 분석하였다. 최대 잔류 주응력의 크기는 AlN/W 접합체보다 모재간 열팽창계수 차이가 큰 AlN/Cu 접합체에서 더 크게 나타났으며, 접합계면에 인접한 AlN 세라믹스 자유표면에 인장 성분의 응력집중이 확인되었다. 모재와 삽입금속의 탄소성 변형을 모두 고려할 경우, AlN/Cu 접합체의 경우 연질의 삽입금속에 의해 최대 잔류 주응력이 감소하여 소성변형에 의한 응력완화 효과가 있음을 확인하였으나, 100μm 이상으로 삽입금속 두께를 증가시키더라도 잔류 주응력의 크기는 더 이상 크게 감소하지 않았다. 측정된 최대 접합강도는 AlN/Cu와 AlN/W 접합체에서 각각 52 MPa와 108 MPa이었으며, 파단 형태는 AlN/Cu 접합체는 AlN 자유표면으로부터 AlN 내부로 큰 각도를 이루면 진행되는 돔형의 파단이, AlN/W 접합체에서는 접합계면의 삽입금속층을 따라 AlN 측에서 파단이 일어나는 형태를 보였다.