본 연구에서는 가로수로 식재 한 메타세쿼이아 214본을 대상으로 시각적 활력 평가와 형성층전기저항계(JunsMeter) 측정 결과를 비교하였다. 시각적 활력 평가로 경북 예천군에서는 모든 활력 단계를 관찰하였고, 상주시에서는 ‘매우 양호’와 ‘양호’ 단계만 나타났다. JunsMeter의 측정 평균값은 예천(75.48)보다 상주(86.99)에서 높았다(P=0.01). 방위별 JunsMeter 측정에서는 예천군의 서쪽(71.29)에서 가장 낮았다. 예천과 상주에서 시각적 활력 평가로 구분한 3개 그룹과 JunsMeter 측정값과 일관되게 나타났다.
PURPOSES: The purpose of this study is to provide the method of how to measure the coefficient of thermal expansion of concrete using temperature compensation principle of electrical resistance strain gauge.
METHODS : The gauge factor compensation method and thermal output(temperature-induced apparent strain) correction method of selftemperature compensation gauge were investigated. From the literature review, coefficient of thermal expansion measurement method based on the thermal output differential comparison between reference material(invar) and unknown material(concrete) was suggested.
RESULTS: Thermal output is caused by two reasons; first the electrical resistivity of the grid conductor is changed by temperature variation and the second contribution is due to the differential thermal expansion between gauge and the test material. Invar was selected as a reference material and it、s coefficient of thermal expansion was measured as 2.12×10-6m/m/℃. by KS M ISO 11359-2. The reliability of the suggested measurement method was evaluated by the thermal output measurement of invar and mild steel. Finally coefficient of thermal expansion of concrete material for pavement was successfully measured as 15.45×10-6m/m/℃.
CONCLUSIONS: The coefficient of thermal expansion measurement method using thermal output differential between invar and unknown concrete material was evaluated by theoretical and experimental aspects. Based on the test results, the proposed method is considered to be reasonable to apply for coefficient of thermal expansion measurement.
The failure behaviours of unidirectional pultruded carbon fiber reinforced polymer (CFRP) composites were monitored by the electrical resistance measurement during tensile loading, three-point-bending, interlaminar shear loading. The tensile failure behaviour of carbon fiber tows was also investigated by the electrical resistance measurement. Infrared thermography non-destructive evaluation was performed in real time during tensile test of CFRP composites to validate the change of microdamage in the materials. Experiment results demonstrated that the CFRP composites and carbon fiber tows were damaged by different damage mechinsms during tensile loading, for the CFRP composites, mainly being in the forms of matrix damage and the debonding between matrix and fibers, while for the carbon fiber tows, mainly being in the forms of fiber fracture. The correlation between the infrared thermographs and the change in the electrical resistance could be regarded as an evidence of the damage mechanisms of the CFRP composites. During three-point-bending loading, the main damage forms were the simultaneity fracture of matrix and fibers firstly, then matrix cracking and the debonding between matrix and fiber were carried out. This results can be shown in Fig. 9(a) and (b). During interlaminar shear loading, the change in the electrical resistance was related to the damage degree of interlaminar structure. Electrical resistance measurement was more sensitive to the damage behaviour of the CFRP composites than the stress/time curve.